Fault
Possible Causes
Ø Broken wire
F0080
Ø Signal out of limits
ADC lost input
signal
External fault triggered
F0085
External Fault
Software error or processor failure
F0101
Stack
Overflow
PI Feedback below minimum value
F0221
P2268
PID Feedback
below min.
value
PI Feedback above maximum value
F0222
P2267
PID Feedback
above max.
value
Fault value:
F0450
1
Some of the power section tests
BIST Tests
have failed
Failure
(Service mode
2. Some of the control board tests
only)
have failed
4
Some of the functional tests have
failed
8
Some of the IO module tests
have failed
16 The internal RAM has failed its
check on power-up
Load conditions on motor indicate
F0452
belt failure or mechanical fault.
Belt Failure
Detected
MICROMASTER 440
Operating Instructions
6SE6400-5AC00-0BP0
7 MICROMASTER 440 specifications
Diagnose & Remedy
Check connection to analogue input
Disable input for fault trigger
1. Run self test routines
2. Change inverter
1. Change value of P2268
2. Adjust feedback gain
1. Change value of P2267
2. Adjust feedback gain
1. Inverter may run but certain actions will not
function correctly
2. Replace inverter
Check the following:
1. No breakage, seizure or obstruction of drive
train.
2. Proper operation of external speed sensor, if
in use.
3. P0402 (pulse per min at rated speed), P2164
(hysteresis freq. deviation) and P2165 (delay
time for permitted deviation) must have
correct values.
4. P2155 (threshold frequency f1), P2157
(threshold frequency f2), P2159 (threshold
frequency f3), P2174 (upper torque threshold
1), P2175 (lower torque threshold 1), P2176
(delay T_Torque), P2182 (upper torque
threshold 2), P2183 (lower torque threshold
2), P2184 (upper torque threshold 3) and
P2185 (lower torque threshold 3) must have
correct values.
Reac-
tion
OFF2
OFF2
OFF2
OFF2
OFF2
OFF2
OFF2