7. Function specification
7.1 Transfer function
1)
Standard monitor OS
Font data
Communication driver
Project data
2)
Project data
Resource data
PC
(GT Designer2, GT Designer3)
Data
Transfer direction
selection
Project
Resource
switch
data
data
1) PC
--
Memory loader
2) Memory loader
--
PC
PROJECT +
OS
3) Memory loader
GOT
PROJECT
PROJECT +
1
OS*
4) GOT
Memory loader
PROJECT
*1 Ver.01.08.00 or later of the standard monitor OS of the GT10 is applicable.
*2 Ver.01.11.00 or later of the standard monitor OS of the GT10 is applicable.
*3 Ver. 2.91V or later of GT Designer2 or Ver. 1.01B or later of GT Designer3 are
applicable.
7.2 Password reset function on the GOT
When reading out the project data from the memory loader, if the password is set in
the project data, password entry screen will appear on the GOT.
After entering the password, password is reset by pressing the ENT key on the
screen. The data will be transferred from the GOT to the memory loader.
The operation procedure is described below.
When this function is used, Ver.01.08.00 or later of the standard monitor OS of the
GT10 is required.
1) When the upload is started, password
entry screen will appear on the GOT
Touch the "INPUT" key.
2) After inputting password, touch the "ENT"
key.
3) When the password matches, a message
notifying Password correct is display.
Touch the
ESC
button to close the
screen.
When the password does not match, an
error message is displayed.
If
button is touch it returns to the
OK
password input screen again.
3)
Standard monitor OS
Font data
Communication driver
Project data
4)
Standard monitor OS
Communication driver
GT1020, GT1030
Project data
Resource data
Memory loader
: Available to transfer
Transfer data
Operation
Font
Standard
Communication
*2
monitor OS
driver
data
After all data in the memory loader is deleted, the data
*3
selected with GT Designer2 or GT Designer3 is written
to the memory loader all at once.
The project data or resource data is read out from the
memory loader to a PC.
*4
All data in the memory loader is written to the GOT.
Only the project data in the memory loader is written
to the GOT.
After all data in the memory loader is deleted, all data
in the GOT is read out to the memory loader.
After all data in the memory loader is deleted, only the
project data and resource data in the GOT are read
out to the memory loader.
*4 It takes longer time to transfer the font data than to transfer the standard
monitor OS and communication driver.
(It takes approximately 1 minute and 45 seconds to transfer "Standard
monitor OS + Communication driver". It takes approximately 8 minutes to
transfer "Standard monitor OS + Communication driver + Font data".)
Japanese (supporting Europe) is installed in the GT10 before shipment from
the factory.
It is not necessary to transfer the font data when the used font is not changed.
7.3 Error display function
If an error occurs between the GOT and the memory loader during the transfer, an
error message will appear on the GOT screen.
Apply remedies according to the display.
Chapter 12 Troubleshooting
Turning OFF and ON the power or touching the screen will close the error message
screen.
When this function is used, Ver.01.08.00 or later of the standard monitor OS of the
GT10 is required.
Error message on the GOT
8. Installation of Driver, Setting Software
When the communication between a PC (GT Designer2 Ver.2.77F or later, GT
Designer3 Ver.1.01B or later) and the memory loader is performed, driver
installation, communication port setting is required.
8.1 Driver installation
When the communication between a PC (GT Designer2, GT Designer3) and the
memory loader is performed, driver installation is required. Refer to the following
manual for details about driver installation.
GT Designer2 Version
Basic Operation/Data Transfer Manual
GT Designer3 Version
Screen Design Manual (Fundamentals)
8.2 Confirmation of communication port
®
Windows
XP example follows.
®
 In Windows
XP, click [ Start ]
[ Settings ]
[ Performance and Maintenance ]
Manager (D) ] and the window below will be displayed.
: Unavailable to transfer
Please confirm the COM number to which the USB driver is allocated (COM and
LPT).
®
®
 If using Windows
98, Windows
98SE, Windows
®
Windows
2000
A screen that is equivalent to the one below is displayed by clicking [ My
Computer ]
[ Control Panel ]
[ System ]
menu of the personal computer.
®
 If using Windows
Vista. A screen that is equivalent to the one below is
displayed by clicking [ Start ]
[ Control Panel ]
menu of the personal computer.
Check following:
- GT10-LDR is indicated at A).
- GT10-LDR (COM *) is indicated at B).
* indicates the COM number used in Memory loader.
- Install the GT Designer2 or GT Designer3 again when
Select the GT Designer2 or GT Designer3 COM number as the COM number
currently assigned on the screen above.
8.3 Setting GT Designer2
Click [ Communication ]
[ Communicate with GT10-LDR ]
configuration tab ].
Select the same COM number as the COM number of the personal computer when
the setting communication port screen appears.
Click [ Update ].
8.4 Setting GT Designer3
Click [ Communication ]
communicate with GT10-LDR screen.
Click the [ Communication Configuration... ] tab to display the communication
configuration dialog.
Select the same COM number as the COM number of the personal computer when
the setting communication port screen appears.
Click [ OK ].
[ Control Panel ]
[ System ]
[ Hardware ]
[ Device
®
Millennium Edition or
9. Transfer procedures between a PC and the Memory
[ Device Manager ] in the
loader
9.1 To write the data from a PC (GT Designer2 Ver.2.77F or later,
[ Device Manager ] in the
GT Designer3 Ver.1.01B or later) to the memory loader
The standard monitor OS, communication driver, font data, and project data are
written from a PC (GT Designer2, GT Designer3) to the memory loader. The
operation procedure is described below.
B)
PC
(GT Designer2, GT Designer3)
1) Turn OFF the Write protection switch.
A)
2) Connect a PC (GT Designer2, GT Designer3) to the memory loader with USB
cable supplied.
3) Write the data from a PC (GT Designer2, GT Designer3) to the memory loader.
Refer to the following manual for details about operating instructions of GT
Designer2 or GT Designer3.
GT Designer2 Version
GT Designer3 Version
is displayed.
[ Communication
[ Communicate with GT10-LDR... ] to display the
Standard monitor OS
Communication driver
Font data
Project data
Memory loader
Basic Operation/Data Transfer Manual
Screen Design Manual (Fundamentals)

Advertisement