RUGGEDCOM RX1500
Installation Guide
Technical Specifications
The following sections provide important technical specifications related to the device and available modules:
•
Section 4.1, "Power Supply Specifications"
•
Section 4.2, "Failsafe Relay Specifications"
•
Section 4.3, "Copper Serial Port Specifications"
•
Section 4.4, "Copper Ethernet Port Specifications"
•
Section 4.5, "Fiber Optic Ethernet Port Specifications"
•
Section 4.6, "Operating Environment"
•
Section 4.7, "RUGGEDCOM APE Specifications"
•
Section 4.8, "Mechanical Specifications"
Section 4.1
Power Supply Specifications
Power Supply Type
HI
HIP
24
24P
48
48P
a
Power consumption varies based on the device configuration.
b
(T) denotes time-delay fuse.
Section 4.2
Failsafe Relay Specifications
Maximum Switching Voltage
30 VDC
Power Supply Specifications
Input Range
Min
88 VDC
300 VDC
85 VAC
264 VAC
88 VDC
300 VDC
85 VAC
264 VAC
15 VDC
36 VDC
15 VDC
36 VDC
36 VDC
72 VDC
36 VDC
72 VDC
Rated Switching Current
Internal Fuse Rating
Max
3.15 A(T)
3.15 A(T)
10 A(T)
10 A(T)
3.15 A(T)
3.15 A(T)
5 A
Technical Specifications
Max. Power
Consumption
b
65 W
b
65 W
b
52 W
b
52 W
b
52 W
b
52 W
c
Isolation
240 V
rms
Chapter 4
a