Panasonic KX-TDA50 Pc Programming Manual page 168

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA50:
Table of Contents

Advertisement

3.16 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Feature Manual References
None
Pulse Dial—Maximum BREAK Width
Specifies the maximum length of the break signal in a pulse dial.
Default
112 ms
Value Range
8 ´ n (n=9–20) ms
Maintenance Console Location
3.16 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
Pulse Dial—Minimum MAKE Width
Specifies the minimum length of the make signal in a pulse dial.
Default
8 ms
Value Range
8 ´ n (n=1–5) ms
Maintenance Console Location
3.16 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
Flash—Flash Signal Detection (OPX)
Enables the PBX to detect hookswitch flash signals from an SLT connected to an OPX.