Checking The Hydraulic Fluid Level - Toro 22323 Operator's Manual

Compact utility loader
Hide thumbs Also See for 22323:
Table of Contents

Advertisement

Checking the Hydraulic Fluid
Level
Service Interval: Every 25 hours
Hydraulic Tank Capacity: 12 US gallons (45.4 l)
Use 10W-30 or 15W-40 detergent, diesel engine oil (API
service CH-4 or higher).
1. Remove the attachment, if one is installed; refer to
Removing an Attachment.
2. Park the traction unit on a level surface, lower the
loader arms, and fully retract the tilt cylinder.
3. Stop the engine, remove the key, and allow the
engine to cool.
4. Open the hood.
5. Clean the area around the filler neck of the hydraulic
tank (Figure 17).
Figure 17
1. Hydraulic filler neck cap
6. Remove the cap from the filler neck and check the
fluid level on the dipstick (Figure 18).
The fluid level should be between the marks on the
dipstick.
1. Filler neck
7. If the level is low, add enough fluid to raise it to the
proper level.
8. Install the cap on the filler neck.
9. Close the hood.
19
Figure 18
2. Dipstick