Diagnostic ACE Display Functions
1.
Overlay decal (English shown)
2.
"Inputs Displayed" LED (Red)
3.
"Outputs Displayed" LED (Green)
4.
Toggle button
Figure 26
Using "Inputs Displayed" (Red Text)
1.
LED lit if oil level is too high
2.
LED lit if oil level is OK
3.
LED lit if oil level is too low
4.
LED lit if oil is too hot
5.
LED lit if system air leak has been detected
6.
One or two LEDs lit displaying the relative
position of the Turfdefender's internal float.
7.
"Inputs Displayed" LED "ON" (Red)
Normal Operation:
a. "Oil Level OK" LED lit
b. 1 or 2 LEDs lit on left column
Figure 27
Using "Outputs Displayed" (Green Text)
Normal Operation:
a. "Valve ON" LED lit steadily
b. "Self-Diagnostic" LED lit steadily
c. "DATA LINE" LED lit steadily
d. "Alarm ON" LED lit temporarily
Problem Diagnosed: The appropriate LED will blink
to identify the problem
Figure 28
Operation
25