Checking The Pump Case Oil Level - Toro 09802 Operator's Manual

Hide thumbs Also See for 09802:
Table of Contents

Advertisement

for the hydraulic system oil is available in 2/3 oz. (20
ml) bottles. One bottle is sufficient for 4-6 gal (15-22
1) of hydraulic oil. Order part no. 44-2500 from your
authorized Toro distributor.
1. Position the machine on a level surface.
2. Release the hood latches and raise the hood.
3. Check the level of hydraulic oil on the sight gauge
(Figure 10). The fluid level should be up to the
middle of the gauge window.
Figure 10
1. Sight gauge
4. If the fluid level is low, remove the filler cap and
add enough hydraulic oil to bring the oil up to the
proper level.
5. Lower the hood and secure the latches.
Note: The oil and filter must be changed
immediately when any contamination, sludge, water
or condensation appears in oil or on sight gauge.
Determine and correct oil contamination problem
before restarting engine and operating machine.
Checking the Pump Case Oil
Level
Service Interval: Before each use or daily
After the first 25 hours
Every 200 hours
The pump crank case is filled at the factory with
approximately 40 ounces of Mobil DTE Extra Heavy
oil. Check the oil level on the dipstick before the engine
is first started and daily thereafter. Change the oil
initially after 25 hours of operation, thereafter change
every 200 hours of operation. See the following chart
for equivalent oils.
2. Filler cap
Shell
Chevron
Conoco
Exxon
Philllips
Sun
76 Lubricants
Castrol
Important: The oil must be changed immediately
when any contamination, sludge, water, or
condensation appears in the oil. Determine and
correct any oil contamination problem before
restarting the engine and operating the machine.
1. Position the machine on a level surface.
2. Release the hood latches and raise the hood.
3. Remove the dipstick/filler cap and check the oil
level on the dipstick. The fluid level should be up to
the FULL mark (Figure 11).
1. Dipstick/filler cap
4. If the fluid level is low, add enough Mobil DTE
Extra Heavy oil or equivalent oil to bring the oil up
to the proper level. Do not overfill.
5. Lower the hood and secure the latches.
17
Morlina Sd 150
AW Machine Oil 150
Multipurpose R&O 0.1 150
Terresstic 150
Magnus Oil 150
Sunvis 150
Turbine Oil 150
Paradene 150 R&O
Figure 11