5.6. 3D pattern test

(Pattern Generator MSHG-600, MSPG-6100 [SUPPORT
HDMI1.4])
* HDMI mode NO. 872 , pattern No.83
(1) Please input 3D test pattern like below (HDMI mode NO.
872 , pattern No.83)
(2) When 3D OSD appear automatically , then select green
button.
(3) Don't wear a 3D Glasses, Check the picture like below
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
5.6.1. Overview
▪ Option selection is only done for models in AJ/JA/IL
5.6.2. Method
1) Press ADJ key on the Adj. R/C, then select Country Group
Meun
2) Depending on destination, select Country Group Code or
Country Group then on the lower Country option, select US,
CA, MX. Selection is done using +, - or ►◄KEY

5.7. HDMI ARC Function Inspection

5.7.1. Test equipment
- Optic Receiver Speaker
- MSHG-600 (SW: 1220 ↑)
- HDMI Cable (for 1.4 version)
5.7.2. Test method
(1) Insert the HDMI Cable to the HDMI ARC port from the
master equipment (HDMI2)
(2) Check the sound from the TV Set
(3) Check the Sound from the Speaker or using AV & Optic
TEST program (It's connected to MSHG-600)

5.8. Tool Option Inspection

(1) Press Adj. key on the Adj. R/C, and then check Tool option
Model
Tool 1
Tool 2
55EF9500-
34790
21524
UA
65EF9500-
34793
21524
UA
55EG9200-
33350
21524
UA

5.9. Ship-out mode check (In-stop)

▪ After final inspection, press In-Stop key of the Adj. R/C and
check that the unit goes to Stand-by mode
- 22 -
Tool 3
Tool 4
Tool 5
Tool 6
Tool 7
921
64774
18598
2474
44587
921
64774
18598
2474
44587
897
64774
18598
2474
44587
LGE Internal Use Only
Tool 9
512
512
512

Hide quick links: