engine will stop if the traction shift selector is in
#1 or #2 positions with the parking brake
engaged.
Check the Leak Detector
Operation
The TURF GUARDIAN™ leak detector detects
hydraulic oil system leaks. If the oil level in the main
hydraulic reservoir is lowered by 12–18 cl, the float
switch in the tank will close. After a 1-second delay,
the alarm will sound. Expansion of oil, due to normal
heating during machine operation, will cause oil to
transfer into the auxiliary oil reservoir. The oil is
allowed to return to the main tank when the ignition
switch is turned off.
3
1
2
8
BEFORE START (cold oil)
1. Sight window
2. Solenoid return valve open
3. Filler cap
4. Filler neck
5
Overflow tube
6. Fluid level (cold)
7. No sound
8. Float raised, switch open
9. Hydraulic oil tank
To check system operation
1.
With the ignition switch in the ON position,
move the leak detector switch rearward and hold.
After the one-second time delay elapses, the
alarm should sound.
2.
Release leak detector switch.
4
5
9
Figure 17
1
1. Solenoid return valve closed
2. Fluid level (warm)
3. No sound
4. Float raised, switch open
6
7
1. Fluid level (warm)
2. Warning buzzer
3. Float down, switch closed
To check leak detector system operation
1.
Move the ignition switch to ON. DO NOT
START THE ENGINE.
2.
Remove the hydraulic tank cap and strainer from
the neck of the tank.
3.
Insert a clean rod or screw driver into the tank
neck and gently push down on the switch float
(Fig. 20). The alarm should sound after a one-
second delay.
4.
Release the float; the alarm should stop.
20
4
Figure 18
NORMAL OPERATION (oil warm)
3
Figure 19
LEAK ALERT!
2
3
1
2