Maintenance

Check the blower gearbox impeller for tightness every 50
hours. Torque the impeller shaft bolt to 25 to 25.8 N-m
(220 to 230 in-lb).
Clean grass clippings from the hood, chute, blower, and
cutting unit after each use. Wash the underside of the
cutting unit daily with hose. An excessive buildup of
clippings will impair the collection system performance.
Check the belt tension and wear every 50 hours. To adjust
the belt tension, loosen the idler mounting screws, engage
the idler lever, and push the idler pulley firmly into the
blower belt. Tighten the mounting screws.
The blower gear box should need little maintenance.
Check for leakage every 50 hours. If leakage should
occur, replace the seals and refill it with 2 oz. of high
quality moly disulfide grease. Repack the bearings with
this grease before assembling.
Refer to Cutting Unit and Traction Unit Operator's Manuals
for the service requirements of each.
Keep the unit clean. Ensure that the engine is free of
dirt and chaff. Make sure all fasteners are tight. Check
the deflectors, baffles, and shields for wear and replace
as needed.