JVC TK-C8301RU Instructions Manual page 19

Hide thumbs Also See for TK-C8301RU:
Table of Contents

Advertisement

Connecting the Alarm Input/Output Terminal
Menu settings may be required depending on the connected equipment.
(A page 40)
The default setting has been set to alarm input (IN:ALARM).
Alarm input terminal
Connect the infrared sensor, door sensor, metal sensor, manual switch
sensor and the like.
To prevent noise from entering the internal circuit, supply non-voltage
setting signal to the alarm input signal.
Do not supply voltage.
Using the menu, you can select whether to set to alarm when the
contact is short (MAKE), or when the contact is open (BREAK).
Supply such that the alarm signal stays at a minimum of 200 ms or
more. Otherwise, the alarm signal may not be recognized.
SEE INSTRUCTION
D/N AUTO
OFF
MANUAL
BLC OFF
ON
VIDEO
LCD
CRT
OUT
WIDE-D
ON
OFF
MONITOR TYPE
FOCUS
ADJUST
CLASS 2 ONLY
( U TYPE )
ISOLATED POWER
SET
ONLY ( E TYPE )
Alarm output terminal
Connect to alarm devices such as alarm, indicator, light or buzzer.
The alarm output signal is open collector output and turns ON during
an alarm. (Maximum voltage 16 V, current 30 mA)
This terminal has a polarity. Make sure to connect such that a higher
voltage is output from the + terminal than from the - terminal.
Otherwise, it will result in damages.
AUX(IN)
GND
AUX(OUT)
100K
GND
Connection/Installation
Please use a shielded
*
cable.
E-19