TO access factory mode
1. Turn off monitor(do not turn off PC)
2. Press AUTO , OK and the power simultaneously on the frond control
panel, then press OK wait till the OSD menu come on the screen of
monitor.
Fig.1
3.If OSD menu disappears on the screen of monitor. press OK
again(anytime), then the OSD menu comes on the screen again.
to select OSD menu.
4. Use
to access/confirm the selection.
5. Use
Move the cursor to yellow area (see red circle on Fig.1)
press OK button to access to factory mode.(see Fig.2)
PC mode WHITE-D adjustment (B)
1 Apply 1280X1024/60Hz mode with 64 gray level pattern as Fig
3. Set main controls brightness control at 100% and contrast to
50% on User mode. Set color setting at original panel color on
User mode. Move cursor to "Auto-SUB" item on factory mode,
press "OK" key to activate this function.

Display Adjustment

Fig.2
Fig.3
2. Apply a 1280x1024/60Hz signal with white pattern.Set
brightness control at 100% and contrast control at 50%. Adjust
the R.G.B gain to reach special color temperature on center of screen.
2.1 Aim the probe CA-A30 at the center of screen as Fig. 4
2.2 Remove the lens protective cover of probe CA-A30.
2.3 Set Measuring/viewing selector to Measuring position for reset
analyzer. (Zero calibration) as Fig. 5
2.4 Turn on the colour analyzer (CA-110).
2.5 Press 0-CAL button to start reset analyzer. See Fig. 6
Fig.4
O-CAL
2.6 Switch light probe to Viewing position.
2.7 Move the Lens barrel forward or backward to get clear image
as shown in Fig. 7
2.8 Switch light probe to Measuring position. It should be able to
indicate colour value on the CA-110.
200P7 LCD
19
Go to cover page
Fig.6
Fig.7

Advertisement