Advertisement

Quick Links

Iris Camera

Operating Instructions

BM-ET500
Model No.
ACCEPT
REJECT
READY
Before attempting to connect or operate this product,
please read these instructions carefully and save this manual for future use.

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic BM-ET500

  • Page 1: Operating Instructions

    Iris Camera Operating Instructions BM-ET500 Model No. ACCEPT REJECT READY Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use.
  • Page 2 You should note the serial number of this unit in the space provided and retain this book as a permanent record of your purchase to aid identification in the event of theft. Model No. BM-ET500 Serial No. For U.S.A...
  • Page 3: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this apparatus near water. 6) Clean only with dry cloth. 7) Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 8) Do not use near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
  • Page 4: Table Of Contents

    IMPORTANT SAFETY INSTRUCTIONS ... 3 PREFACE ... 5 FEATURES ... 6 NOTIFICATION ABOUT THIS DOCUMENT ... 7 TRADEMARKS ... 7 LIMITATION OF LIABILITY ... 7 DOCUMENT CONVENTION ... 8 PRECAUTIONS ... 9 MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ... 10 INSTALLATIONS AND CONNECTIONS ...
  • Page 5: Preface

    PREFACE Iris Camera BM-ET500 is used in an access control system. The iris camera, which captures a user's iris image with the control by Control Unit BM-ED500, is available for following uses. (Control Unit BM-ED500 is sold separately, however, it must be used in combination with the iris camera.) •...
  • Page 6: Features

    • Access control system can be composed. Iris cameras, control units, and the administration PC can compose an access control system in combination with access control panels* and electric locks* These devices are independent to BM-ET500. , etc.
  • Page 7: Notification About This Document

    NOTIFICATION ABOUT THIS DOCUMENT • This document describes basic operating instructions of Iris Camera BM-ET500. • The operating instructions supplied to BM-ED500 Control Unit describes operating instructions, examples of system com- position, and installation guide of the control unit. The instruction manuals supplied to Administration Software BM-ES500E, which is the software required for iris data enrollment, describe how to use the administration software.
  • Page 8: Document Convention

    The PC can administer control units in the LAN. Control Unit: Panasonic Control Unit BM-ED500, which is used for iris enrollment/recognition, and controls electric locks (This product is sold separately, however, it must be used in combination with iris cameras.) Distribution: To transfer enrolled data from the administration PC to control units and to save the data in the control units Enrollment: To save a user's iris data associated with the individual information (name and ID data, etc.) in the administration PC...
  • Page 9: Precautions

    PRECAUTIONS • Refer all work related to the installation of this product to qualified service personnel or system installers. Consult an expert on the load bearing capacity of the installation surface and structure. If the surface is not strong enough, the camera may fall down. Refer to the product specifications for weights.
  • Page 10: Major Operating Controls And Their Functions

    MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS u LED indicator q Status Indicator Shows the status of recognition or enrollment. ACCEPT: Lights up when recognition has been suc- cessfully executed. * Or lights up when enrollment has been successfully executed through iris image capturing. REJECT: Lights up when recognition has not been suc- cessfully executed.
  • Page 11: Installations And Connections

    Top View Keep this area free from obstructions 400 mm {16 in.} 1 300 mm {51 in.} System Instruction (Maximum System) Coaxial cable (BNC) BM-ET500 (For enrollment) General-purpose power supply * (24 V DC) Administration PC* * The use of the Administration PC was not evaluated by UL.
  • Page 12 I Installation The unit can be mounted over the wall as described. 1. Attach the anchor into the wall, and then attach the sup- plied mounting bracket to the anchor. (Refer to the fig- ure in p.14.) The anchor bolt should meet the standards shown in the illustration.
  • Page 13 4. Attach the unit to the mounting bracket. You need to make a hole of approx. ø 30 mm on the wall to pass the cables out of the rear side. (1) Attach the mounting bracket to the wall. (2) Remove the numeric keyboard.
  • Page 14: Dimensions Of The Mounting Bracket

    DIMENSIONS OF THE MOUNTING BRACKET 180.5 174.5 4-φ10 22.5 180.5 186.5 (Unit of length: mm)
  • Page 15: Adjustments And Maintenance

    ADJUSTMENTS AND MAINTENANCE I Adjustment G Adjusting the Buzzer Level Adjust the buzzer level, which informs you of recognition results, as follows. 1. Open the cover of the numeric keyboard. 2. Insert a Phillips precision screwdriver into the buzzer- level adjustment hole. 3.
  • Page 16: Recognition Procedures

    RECOGNITION PROCEDURES There is two ways of identification: • Iris recognition • ID-and-password authorization Note: When “READY” is blinking, recognition will be unavailable. Wait until the indicator is on, not blinking. I Iris Recognition The procedures are as follows. 1. Stand in front of the unit and turn your face to the center front panel.
  • Page 17: I Id-And-Password Authorization

    Notes: • The capturing range is as follows. Top View 33° 300 mm {12 in.} 44 mm {1-7/10 in.} 0 mm {0 in.} • The height of the unit, shown in the figure, is recommendation. Center of optical axis and upside/downside limit of eye position will differ depending on the installation height.
  • Page 18: Additional System Components

    ADDITIONAL SYSTEM COMPONENTS I Control Unit BM-ED500 This product is necessary for iris data recognition/enroll- ment and controlling an electric lock. I Administration Software BM- ES500E Administration Software BM-ES500E This product is necessary for administering iris data, ID data and passwords.
  • Page 19: Troubleshooting

    TROUBLESHOOTING Check to see the following before request for repair. If a trouble cannot be corrected even after checking and trying remedy, contact your dealer. Problem System does not power up. Enrollment/Recognition is invalid. Check item The power of the control unit may be turned off.
  • Page 20 The status indicator does not light up. The buzzer does not sound. The power of the control unit may be turned off. (The control unit supply the power to the unit.) Third party external power may be off. This unit may be disconnected from the control unit.
  • Page 21: Specifications

    SPECIFICATIONS General Power source: Power consumption: Iris recognition time: Ambient operating temperature: Ambient operating humidity: Dimensions: Weight: Input/Output CCTV camera output: * The external power supply should meet the following specifications and must be a UL Listed access control power limited device.
  • Page 22: Standard Accessories

    STANDARD ACCESSORIES Operating instructions (This document)* The following parts are used during installation procedures. Mounting bracket ... 1 pc. Screw nut (M5) ... 1 pc. Tamperproof screw driver tool* Video output cable (for the built-in color CCTV camera) ... 1 pc. Operating instruction sticker* You will use it for installation.
  • Page 24 Unit of Matsushita Electric Corporation of America Security Systems Group www.panasonic.com/cctv Executive Office: One Panasonic Way 3E-7, Secaucus, New Jersey 07094 Zone Office Eastern: One Panasonic Way, Secaucus, NJ 07094 (201) 348-7303 Central: 1707 N.Randal Road, Elgin, IL 60123 (847) 468-5205 Western: 6550 Katella Ave., Cypress, CA 90630 (714) 373-7840...

Table of Contents