Outline dimension drawings
6.3.2

Dedicated motor outline dimension drawings

Dedicated motor (SF-V5RU(H)) outline dimension drawings
SF-V5RU(H)
1K
Connector (for encoder)
MS3102A20-29P
L
A
B
KA
Exhaust
Suction
Direction of
cooling fan wind
XB
F
F
Mark for earthing
N
(grounding)
Earth (ground) terminal (M5)
W
Sliding distance
15
S
Frame leg viewed from above
Section AA
SF-V5RU(H)
,
,
11K
15K
Connector (for encoder)
MS3102A20-29P
L
A
KA
Exhaust
Suction
With guard
wires
Direction of
cooling fan wind
Mark for earthing
F
F
(grounding)
N
Earth (ground)
terminal (M8)
Sliding distance
W
S
Frame leg viewed
from above
Section AA
Dimensions table
SF-V5RU
SF-V5RU1
SF-V5RU3
SF-V5RU4
Frame
Output
Output
Output
Output
No.
(kW)
(kW)
(kW)
(kW)
1.5
90L
2.2
1.5
100L
3.7
2.2
1.5
112M
5.5
3.7
2.2
132S
7.5
5.5
3.7
1.5
132M
11
7.5
5.5
2.2
160M
15
11
7.5
3.7
160L
18.5
180M
22
15
11
18.5
15
5.5
180L
30
200L
30, 45
22, 30
18.5
7.5
55
37
22, 30
11, 15
225S
Note) 1. Install the motor on the floor and use it with the shaft horizontal.
2. Leave an enough clearance between the fan suction port and wall to ensure adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the load side.
3 The size difference of top and bottom of the shaft center height is
4 The 400V class motor has -H at the end of its type name.
170
KL
50
40
D
A
A
E
E
M
For cooling fan (A, B)
A
B
U
V
,
18K
22K
KL
110
B
D
90
A
A
50
XB
E
E
M
4
For cooling fan (A, B, C)
Mass
(kg)
A
B
C
D
E
F
24
256.5
114
90
183.6
70
62.5
33
284
128
100
207
80
70
41
278
135
112
228
95
70
52
303
152
132
266
108
70
62
322
171
132
266
108
89
99
412
198
160
318
127
105
113
434
220
160
318
127
127
138
438.5 225.5
180
363
139.5 120.5
160
200
457.5 242.5
180
363
139.5 139.5
238
483.5 267.5
200
406
159
152.5
255
320
500
277
225
446
178
143
0
-0.5
(1500r/min series)
SF-V5RU(H)
2K
Connector (for encoder)
MS3102A20-29P
A
KA
Exhaust
Suction
Direction of
cooling fan wind
Mark for earthing
(grounding)
Earth (ground) terminal (M5)
For motor (U, V, W)
Thermal protector (G1, G2)
W
G1
G2
Earthing (grounding) terminal
SF-V5RU(H)
30K
Connector (for encoder)
MS3102A20-29P
Suction
With guard
wires
Direction of
Mark for earthing
cooling fan wind
(grounding)
For motor (U, V, W)
Earth (ground)
terminal (M12)
Earthing (grounding)
terminal
For thermal protector (G1, G2)
Motor
H
I
KA
KG KL(KP)
L
M
198
53
65
220(210)
425
175
203.5
230
65
78
231
477
200
226
253
69
93
242
478
230
265
288
75
117
256
542
256
265
288
94
117
256
580
256
316
367
105
115
330
735
310
316
367
127
115
330
779
310
359
410
127
139
352
790
335
359
410
146
139
352
828
335
401
145
487
(546)
909
390
446
145
533
(592)
932
428
(standard horizontal type)
,
3K
,
5K
,
7K
L
B
Q
KL
QK
A
A
40
XB
F
F
E
N
W
S
Section AA
,
,
,
37K
45K
55K
L
A
B
140
110
KA
Exhaust
A
A
70
F
F
XB
N
W
S
Section AA
Make sure to earth the earth terminal of the frame installation foot
as well as the earth terminal in the terminal box.
ML
N
XB
Q
QK
R
S
150
56
168.5 24j6
212
180
63
60
45
193
28j6
242
180
70
60
45
200
28j6
268
180
89
80
63
239
38k6
268
218
89
80
63
258
38k6
254
108
323
42k6
298
108
345
42k6
285
121
351.5 48k6
323
121
370.5 55m6
10
361
133
425.5 60m6
342
149
432
65m6
D
E
M
Sliding distance
ML
4
Frame leg viewed
from above
D
E
E
M
Sliding distance
4
Frame leg viewed
from above
(Unit: mm)
Terminal Screw
Size
T
U
W
U,V,W A,B,(C) G1,G2
7
4
8
M6
M4
M4
7
4
8
M6
M4
M4
7
4
8
M6
M4
M4
8
5
10
M6
M4
M4
8
5
10
M6
M4
M4
8
5
12
M8
M4
M4
8
5
12
M8
M4
M4
9
5.5
14
M8
M4
M4
6
16
M8
M4
M4
M10
M4
M4
M10
M4
M4