Mitsubishi Electric FR-A700 Series Instruction Manual page 177

Hide thumbs Also See for FR-A700 Series:
Table of Contents

Advertisement

Outline dimension drawings
Dedicated motor (SF-V5RU(H)) outline dimension drawings
SF-V5RUF(H)
1K
Connector (for encoder)
MS3102A20-29P
LL
KB
LG
Exhaust
Section
AA
Suction
Direction of
cooling fan wind
Earth (ground) terminal (M5)
Mark for earthing (grounding)
SF-V5RUF(H)
,
11K
15K
Connector (for encoder)
MS3102A20-29P
LL
KB
Exhaust
Section
Suction
Direction of
Earth (ground) terminal (M8)
cooling fan wind
Mark for earthing (grounding)
With guard wires
Dimensions table
SF-V5RUF
SF-V5RUF1
SF-V5RUF3
SF-V5RUF4
Flange
Output
Output
Output
Output
Number
(kW)
(kW)
(kW)
(kW)
1.5
FF165
2.2
1.5
FF215
3.7
2.2
1.5
FF215 112M
5.5
3.7
2.2
FF265
7.5
5.5
3.7
1.5
FF265 132M
11
7.5
5.5
2.2
FF300 160M
15
11
7.5
3.7
FF300
18.5
FF350 180M
22
15
11
18.5
15
5.5
FF350
30
FF400
37, 45
22, 30
18.5
7.5
Note) 1. Install the motor on the floor and use it with the shaft horizontal.
For use under the shaft, the protection structure of the cooling fan is IP20.
2. Leave an enough clearance between the fan suction port and wall to ensure adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the load side.
3 The size difference of top and bottom of the shaft center height is
4 The 400V class motor has -H at the end of its type name.
* Consult our sales office.
172
LR
KL
Q
LE
QK
A
B
B
W
S
For cooling fan (A, B)
Section BB
For motor (U, V, W)
For thermal protector (G1, G2)
A
W
G1
G2
B
U
V
,
,
18K
22K
LR
Q
LG
LE
KL
QK
AA
A
B
B
A
W
S
Section BB
For cooling fan (A, B, C)
Frame
Mass
No.
(kg)
D
IE
KB
KD
90L
26.5
183.6
198.5
27
100L
37
207
130
213
27
46
228
141
239
27
132S
65
266
156
256
27
70
266
156
294
27
110
318
207
318
56
160L
125
318
207
362
56
160
363
230
378.5
56
185
180L
270
200L
406
255
485
90
290
0
-0.5
(1500r/min series)
SF-V5RUF(H)
2K
Connector (for encoder)
MS3102A20-29P
LN LZ
Suction
A
Direction of
cooling fan wind
Earth (ground) terminal (M5)
Mark for earthing (grounding)
Earthing (grounding)
terminal
SF-V5RUF(H)
30K
Connector (for encoder)
MS3102A20-29P
LN LZ
Suction
Direction of
Earth (ground) terminal (M12)
cooling fan wind
Mark for earthing (grounding)
With guard wires
For motor (U, V, W)
Earthing (grounding)
terminal
For thermal protector (G1, G2)
Motor
KL
LA
LB
LC
LE
LG
LL
220
165
130j6
200
3.5
12
402
231
215
180j6
250
4
16
432
242
215
180j6
250
4
16
448
256
265
230j6
300
4
20
484
256
265
230j6
300
4
20
522
330
300
250j6
350
5
20
625
330
300
250j6
350
5
20
669
352
350
300j6
400
5
20
690
346
400
350j6
450
5
22
823.5
(flange type)
,
,
,
3K
5K
7K
LL
KB
LR
Q
LG
LE
QK
Exhaust
Section
AA
B
B
W
S
Section BB
,
,
37K 45K
LL
LR
KB
Q
QK
LG
LE
Exhaust
Section
AA
B
B
KD
W
S
Section BB
Make sure to earth the earth terminal of the flange section
as well as the earth terminal in the terminal box.
Shaft End
LN
LZ
LR
Q
QK
S
T
4
12
50
50
40
24j6
7
4
14.5
60
60
45
28j6
7
4
14.5
60
60
45
28j6
7
4
14.5
80
80
63
38k6
8
4
14.5
80
80
63
38k6
8
4
18.5
110
110
90
42k6
8
4
18.5
110
110
90
42k6
8
4
18.5
110
110
90
48k6
9
8
18.5
140
140
110
60m6
11
KL
LN LZ
A
A
KL
LN LZ
A
A
(Unit: mm)
Terminal Screw Size
U
W
U,V,W A,B,(C) G1,G2
4
8
M6
M4
M4
4
8
M6
M4
M4
4
8
M6
M4
M4
5
10
M6
M4
M4
5
10
M6
M4
M4
5
12
M8
M4
M4
5
12
M8
M4
M4
5.5
14
M8
M4
M4
*
7
18
M10
M4
M4

Advertisement

Table of Contents
loading

Table of Contents