ALARM CONTROL

■ Alarm Acknowledgement (ACK)

By acknowledging an alarm occurrence on an associated
monitor, you can control alarm pictures.
● WV-CU950/650
While a monitor in the alarm mode status is selected, press
the ACK button. (During the alarm mode status, "Alarm"
sign is blinking on the LCD.)
The alarm event will be acknowledged. ("Alarm" sign will
change to steady light.)
● WV-CU360C/CJ
While a monitor in the alarm mode status is selected, press
the ACK button. (During the alarm mode status, the alarm
number is blinking on the LCD.)
The alarm will be acknowledged. (The alarm number will
change to steady light.)
In the ACK status, the following operations are available.

■ Camera Control

You can control panning/tilting of cameras, or move cam-
eras to preset positions.

■ Alarm Picture Change

When two or more alarms are occurring, you can change
alarm pictures displayed on the monitor in order or reverse
order.
● WV-CU950/650
To change alarm pictures on the monitor, press the + or –
button. The alarm pictures will be displayed in order or
reverse order.
68
● WV-CU360C/CJ
To change alarm pictures on the monitor, press the NEXT
or PREV button. The alarm pictures will be displayed in
order or reverse order.

■ Alarm Individual Reset

You can reset each acknowledged alarm separately, and
return to the status before alarm occurrence. While two or
more alarms are occurring, the system will remain in the
alarm mode even after an alarm reset.
To reset an acknowledged alarm, press the ACK button.
The alarm will be reset.
Notes:
• If the alarm event is set to OFF, an alarm will not be
acknowledged. The alarm will be reset by every press-
ing the ACK button.
• If AUTO RESET has been set to ON, alarms will be reset
automatically after the specified time. Refer to p.
ALARM of SETUP MENU.

■ Alarm Monitor Reset

You can reset all the alarms occurred to the selected moni-
tor.
While the selected monitor is in the alarm mode status,
1
press the ALM RESET*
(or RESET*
occurred to the monitor will be reset, and the monitor dis-
play will return to the status before the alarm occurrence.
1
*
WV-CU950/650
2
*
WV-CU360C/CJ
Note: Alarm monitor reset is also available by supplying
alarm recover signals to the unit.

■ Alarm All Reset

You can reset all the alarms occurred to the system.
● WV-CU950/650
Press the ALM ALL RESET*
holding down the SHIFT button. All the alarms occurred to
the system will be reset.
1
*
WV-CU950/650
2
*
WV-CU360C/CJ
2
) button. All the alarms
1
2
(or ALL RESET*
) button while