Siemens RUGGEDCOM RSG2488 Installation Manual

Hide thumbs Also See for RUGGEDCOM RSG2488:
Table of Contents

Advertisement

RUGGEDCOM RSG2488
Installation Guide
4/2015
RC1048-EN-04
Preface
Introduction
Installing the Device
Communication Ports
Technical Specifications
Dimension Drawings
Certification
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RSG2488

  • Page 1 Preface Introduction Installing the Device RUGGEDCOM RSG2488 Communication Ports Technical Specifications Dimension Drawings Installation Guide Certification 4/2015 RC1048-EN-04...
  • Page 2: Security Information

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3: Table Of Contents

    RUGGEDCOM RUGGEDCOM RSG2488 Installation Guide Table of Contents Table of Contents Preface ........................ Alerts ..............................v Related Documents ..........................v Accessing Documentation ........................v Training .............................. vi Customer Support ..........................vi Chapter 1 Introduction ......................1.1 Feature Highlights ........................1 1.2 Description ..........................
  • Page 4 RUGGEDCOM RUGGEDCOM RSG2488 Table of Contents Installation Guide 2.8.1 Protection On Twisted-Pair Data Ports ................23 2.8.2 Gigabit Ethernet 1000Base-TX Cabling Recommendations ..........23 Chapter 3 Communication Ports ..................3.1 Copper Ethernet Ports ........................ 25 3.2 Fiber Optic Ethernet Ports ......................28 3.3 SFP Optic Ethernet Ports ......................
  • Page 5: Preface

    Installation Guide Preface Preface This guide describes the RUGGEDCOM RSG2488. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 6: Training

    Siemens sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: • Online Visit http://www.siemens.com/automation/support-request...
  • Page 7: Introduction

    Introduction Introduction The RUGGEDCOM RSG2488 is a utility grade, fully managed, industrial Ethernet switch designed to operate reliably in harsh environments. With a rugged metal enclosure and an optional conformal coating, the RUGGEDCOM RSG2488 provides a high level of immunity to electromagnetic interference and heavy electrical surges, and can withstand temperatures between -40 and 85 °C (-40 and 185 °F).
  • Page 8: Description

    • Conformal coated printed circuit boards (optional) Section 1.2 Description The RUGGEDCOM RSG2488 features various ports, controls and indicator LEDs on the front panel for connecting, configuring and troubleshooting the device. Figure 1: RUGGEDCOM RSG2488 1. Power Module Indicator LEDs 2.
  • Page 9: Precision Time Protocol (Ptp) Support

    RUGGEDCOM RUGGEDCOM RSG2488 Chapter 1 Installation Guide Introduction Section 1.3 Precision Time Protocol (PTP) Support The Precision Time Protocol (PTP) module adds the ability to provide time synchronization via Ethernet using the Precision Time Protocol (PTP) and Network Time Protocol (NTP), and to synchronize with an external IRIG-B source or GPS network.
  • Page 10: Am And Ttl Outputs

    Chapter 1 RUGGEDCOM RUGGEDCOM RSG2488 Introduction Installation Guide Synchronization Source Without PTP Card With PTP Card û ü NTP (Network Time Protocol) is the standard for synchronizing the clocks of computer systems throughout the Internet and is suitable for systems that require accuracies in the order of 1 ms.
  • Page 11: Ieee 1588 Support

    RUGGEDCOM RUGGEDCOM RSG2488 Chapter 1 Installation Guide Introduction Figure 3: IRIG-B Simplified Circuit Schematic 1. Source 2. Cabling 3. Device The maximum number of devices (N) that can be connected to the source is determined by checking if the source...
  • Page 12 RUGGEDCOM RUGGEDCOM RSG2488 Chapter 1 Installation Guide Introduction IEEE 1588 Support...
  • Page 13: Installing The Device

    IMPORTANT! Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 14: Mounting The Device To A Rack

    Chapter 2 RUGGEDCOM RUGGEDCOM RSG2488 Installing the Device Installation Guide NOTE For detailed dimensions of the device with either rack, DIN rail or panel hardware installed, refer to Chapter 5, Dimension Drawings. The following sections describe the various methods of mounting the device: •...
  • Page 15: Mounting The Device On A Din Rail

    RUGGEDCOM RUGGEDCOM RSG2488 Chapter 2 Installation Guide Installing the Device Section 2.1.2 Mounting the Device on a DIN Rail For DIN rail installations, the RSG2488 can be ordered with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
  • Page 16: Installing The Gps Antenna (If Required)

    IMPORTANT! A Radio Frequency (RF) site survey is recommended prior to any installation to help determine the best location for the GPS antenna. For assistance, contact a Siemens Sales representative. NOTE Although it is impossible to protect the antenna from a direct lightning strike, the antenna and connected components can be protected from secondary effects through site selection and by installing protection devices.
  • Page 17 • Line amplifier or bandpass filter (optional) NOTE Siemens offers an antenna kit for the RSG2488 , which includes a GPS antenna, mounting bracket and coaxial cable. For more information, contact a Siemens Sales representative. To promote signal reception and avoid signal saturation at the receiver input, the overall GPS system requires a relative gain between 5 and 18 dBi.
  • Page 18: Connecting Power

    Chapter 2 RUGGEDCOM RUGGEDCOM RSG2488 Installing the Device Installation Guide little as possible. To achieve minimum RF exposure, install the device when it is configured not to transmit and set it to operational mode remotely, rather than having a technician enable transmission on-site.
  • Page 19: Installing/Removing Power Supplies

    RUGGEDCOM RUGGEDCOM RSG2488 Chapter 2 Installation Guide Installing the Device terminals. High voltage wiring is always made to the upper Hi terminal block and low voltage (24/48 V) wiring is always made to the lower Lo terminal block. • Use only #16 gage wiring when connecting terminal blocks.
  • Page 20: Removing The Power Supplies

    Chapter 2 RUGGEDCOM RUGGEDCOM RSG2488 Installing the Device Installation Guide NOTE The power supplies are hot swappable. It is not necessary to disconnect power to the device before installing or removing a power supply. Remove the blank power module assembly or, if equipped, the currently installed power supply. For information about removing power supplies, refer to Section 2.3.1.2, “Removing the Power...
  • Page 21: Connecting High Ac/Dc Power

    RUGGEDCOM RUGGEDCOM RSG2488 Chapter 2 Installation Guide Installing the Device Figure 9: Removing a Power Supply 1. Screws 2. Power Supply 3. Slot Install the blank power module assembly into the empy slot to prevent the ingress of dust and dirt.
  • Page 22: Connecting Low Dc Power

    Chapter 2 RUGGEDCOM RUGGEDCOM RSG2488 Installing the Device Installation Guide Figure 10: AC Terminal Block Wiring 1. Pluggable Terminal Block for HI Power Supplies 2. Screw-Type Terminal Block for HIP Power Supplies 3. Positive/Live (+/L) Terminal for PS1 4. Neutral/Negative (-/N) Terminal for PS1 5.
  • Page 23: Wiring Examples

    RUGGEDCOM RUGGEDCOM RSG2488 Chapter 2 Installation Guide Installing the Device Figure 11: DC Terminal Block Wiring 1. Pluggable Terminal Block for 24P and 48P Power Supply 2. Screw-Type Terminal Block for 24 and 48 Power Supply 3. Positive Terminal for PS1 4.
  • Page 24 Chapter 2 RUGGEDCOM RUGGEDCOM RSG2488 Installing the Device Installation Guide Figure 13: Single Low DC Power Supply Figure 14: Dual High AC/DC Power Supply Wiring Examples...
  • Page 25: Connecting The Failsafe Alarm Relay

    RUGGEDCOM RUGGEDCOM RSG2488 Chapter 2 Installation Guide Installing the Device Figure 15: Dual Low DC Power Supply Figure 16: High AC/DC Power Supply and Low DC Power Supply Section 2.4 Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions. The NO (Normally Open) contact is closed when the unit is powered and there are no active alarms.
  • Page 26: Grounding The Device

    M3 ring or spade lug and torque it to 1.7 N·m (15 lbf-in). Figure 18: Chassis Ground Connection 1. M3 Screw 2. Standoff 3. M3 Ring Lug Section 2.6 Inserting/Removing the MicroSD Card The RUGGEDCOM RSG2488 accepts a microSD card for storing configuration files and/or software updates. Grounding the Device...
  • Page 27: Connecting To The Device

    RUGGEDCOM RUGGEDCOM RSG2488 Chapter 2 Installation Guide Installing the Device CAUTION! Configuration hazard – risk of data loss. The microSD card must not be removed or replaced during normal operation of the device. Make sure the device is powered down before removing or inserting the card.
  • Page 28: Cabling Recommendations

    Chapter 2 RUGGEDCOM RUGGEDCOM RSG2488 Installing the Device Installation Guide IMPORTANT! The serial console and management (MGMT) ports are intended to be used only as temporary connections during initial configuration or troubleshooting. The serial console port implements RS-232 DCE (Data Communication Equipment) on a DB9 connector. The...
  • Page 29: Protection On Twisted-Pair Data Ports

    Section 2.8.1 Protection On Twisted-Pair Data Ports Siemens does not recommend the use of copper cabling of any length for critical, real-time substation automation applications. All copper Ethernet ports on RUGGEDCOM products include transient suppression circuitry to protect against damage from electrical transients and conform with IEC 61850-3 and IEEE 1613 Class 1 standards.
  • Page 30 RUGGEDCOM RUGGEDCOM RSG2488 Chapter 2 Installation Guide Installing the Device Gigabit Ethernet 1000Base-TX Cabling Recommendations...
  • Page 31: Communication Ports

    The RSG2488 supports several 10/100/1000Base-TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) cables with RJ45, M12 (non-bypass), or Siemens's FastConnect RJ45 male connectors. All connectors are directly connected to the chassis ground on the device and can accept CAT-5 shielded twisted-pair (STP) cables.
  • Page 32 Chapter 3 RUGGEDCOM RUGGEDCOM RSG2488 Communication Ports Installation Guide Available Modules Figure 22: 4 × 10/100/1000Base-TX with RJ45 Ports Figure 23: 2 × 10/100/1000Base-TX with RJ45 Ports Figure 24: 4 × 10/100/1000Base-TX with FastConnect Figure 25: 2 × 10/100/1000Base-TX with FastConnect...
  • Page 33 RUGGEDCOM RUGGEDCOM RSG2488 Chapter 3 Installation Guide Communication Ports State Description Green (Solid) Link established Green (Flashing) Activity No link detected Figure 31: M12 Port LED 1. Link/Activity LED The following are the pin-out descriptions for the RJ45, M12, and FastConnect RJ45 male connectors:...
  • Page 34: Fiber Optic Ethernet Ports

    Chapter 3 RUGGEDCOM RUGGEDCOM RSG2488 Communication Ports Installation Guide 10/100/1000Base-Tx Signal Figure 34: 8-Pin M12 X-Coded Ethernet Port Pin Configuration Terminated at GND (Ground) For specifications on the available copper Ethernet ports, refer to Section 4.3, “Copper Ethernet Port Specifications”.
  • Page 35: Sfp Optic Ethernet Ports

    To install an SFP optical port, do the following: CAUTION! Electrical hazard – risk of damage to equipment. Use only components certified by Siemens with RUGGEDCOM products. Damage to the module and device may occur if compatibility and reliability have not been properly assessed.
  • Page 36: Removing An Sfp Optical Port

    Chapter 3 RUGGEDCOM RUGGEDCOM RSG2488 Communication Ports Installation Guide CAUTION! Mechanical hazard – risk of component damage. SFP optical ports are designed to insert in only one orientation. Do not force the port into the module. Remove the port from its packaging.
  • Page 37: Bnc Ports

    RUGGEDCOM RUGGEDCOM RSG2488 Chapter 3 Installation Guide Communication Ports Store the port in an ESD-safe bag or other suitable ESD-safe environment, free from moisture and stored at the proper temperature (-40 to 85 °C or -40 to 185 °F). Section 3.4...
  • Page 38: Installing Modules

    Chapter 3 RUGGEDCOM RUGGEDCOM RSG2488 Communication Ports Installation Guide Section 3.5.1 Installing Modules Upon installing a new module in the device, all the features associated to the module are available in the operating system. For more information, refer to the ROS User Guide for the RSG2488.
  • Page 39 RUGGEDCOM RUGGEDCOM RSG2488 Chapter 3 Installation Guide Communication Ports If the device is installed in a rack, remove it from the rack. Loosen the screws that secure the module. Pull the module from the chassis to disconnect it. Figure 43: Removing a Module 1.
  • Page 40 RUGGEDCOM RUGGEDCOM RSG2488 Chapter 3 Installation Guide Communication Ports Removing Modules...
  • Page 41: Technical Specifications

    RUGGEDCOM RUGGEDCOM RSG2488 Chapter 4 Installation Guide Technical Specifications Technical Specifications The following sections provide important technical specifications related to the device and available modules: • Section 4.1, “Power Supply Specifications” • Section 4.2, “Failsafe Relay Specifications” • Section 4.3, “Copper Ethernet Port Specifications”...
  • Page 42: Copper Ethernet Port Specifications

    Chapter 4 RUGGEDCOM RUGGEDCOM RSG2488 Technical Specifications Installation Guide Parameter Value (Resistive Load) 250 VAC Maximum Switching Voltage 30 VDC 2 A @ 250 VAC Rated Switching Current 2 A @ 30 VDC 150 W Maximum Switching Capacity 500 VA Section 4.3...
  • Page 43: Fast Ethernet (100 Mbps) Optical Specifications

    NOTE • Maximum segment length is greatly dependent on factors such as fiber quality and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages.
  • Page 44: Gps Antenna Specifications

    Chapter 4 RUGGEDCOM RUGGEDCOM RSG2488 Technical Specifications Installation Guide Cable Power Connector Tx λ Tx min Tx max Distance Speed Mode Type Sensitivity Saturation Budget Type (nm) (dBm) (dBm) (km) (μm) (dBm) (dBm) (dB) 1000Base-LX 9/125 1310 -9.5 11.5 1000Base-LX...
  • Page 45: Ptp Specifications

    RUGGEDCOM RUGGEDCOM RSG2488 Chapter 4 Installation Guide Technical Specifications Best results can be achieved with a total gain of 16 dB (includes antenna gain, cable loss, lightning arrestor loss, line amplifier gain and filter loss) at the antenna input. Section 4.6...
  • Page 46: Operating Environment

    Chapter 4 RUGGEDCOM RUGGEDCOM RSG2488 Technical Specifications Installation Guide Parameter 10 Mbps 100 Mbps 1000 Mbps Notes IEEE 802.3z 1000Base-SX/LX IEEE 802.3ab 1000Base-TX IEEE 802.3x Full duplex operation Section 4.8 Operating Environment Parameter Range Comments Ambient Operating Temperature -40 to 85 °C Measured from a 30 cm (11.8 in) radius surrounding the center of...
  • Page 47: Dimension Drawings

    RUGGEDCOM RUGGEDCOM RSG2488 Chapter 5 Installation Guide Dimension Drawings Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. 442.4 Figure 44: Overall Dimensions...
  • Page 48 Chapter 5 RUGGEDCOM RUGGEDCOM RSG2488 Dimension Drawings Installation Guide 483.5 465.2 21.1 Figure 45: Rack Mount Dimensions...
  • Page 49 RUGGEDCOM RUGGEDCOM RSG2488 Chapter 5 Installation Guide Dimension Drawings 480.5 490.6 Figure 46: Panel and Din Rail Mount Dimensions 1. DIN Rail Centerline...
  • Page 50 RUGGEDCOM RUGGEDCOM RSG2488 Chapter 5 Installation Guide Dimension Drawings...
  • Page 51: Certification

    RUGGEDCOM RUGGEDCOM RSG2488 Chapter 6 Installation Guide Certification Certification The RUGGEDCOM RSG2488 device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. • Section 6.1, “Agency Approvals” • Section 6.2, “FCC Compliance”...
  • Page 52: Emi And Environmental Type Tests

    Chapter 6 RUGGEDCOM RUGGEDCOM RSG2488 Certification Installation Guide Section 6.4 EMI and Environmental Type Tests The RSG2488 has passed the following EMI and environmental tests. IEC 61850-3 EMI Type Tests NOTE • In the case of an all fiber port configuration, this product meets all Class 2 requirements. Otherwise, all Class 1 requirements are met for copper ports.
  • Page 53 RUGGEDCOM RUGGEDCOM RSG2488 Chapter 6 Installation Guide Certification Test Description Test Levels Severity Levels IEC 61000-4-12 Damped Oscillatory Signal Ports 2.5 kV common, 1 kV differential DC Power Ports mode @ 1 MHz AC Power Ports IEC 61000-4-16 Mains Frequency Voltage...
  • Page 54: Environmental Type Tests

    Chapter 6 RUGGEDCOM RUGGEDCOM RSG2488 Certification Installation Guide Test Description Test Levels IEEE C37.90.3 Enclosure Contact +/-2 kV, +/-4 kV, +/- 8 kV Enclosure Air +/-4 kV, +/-8 kV, +/-15 kV Environmental Type Tests Test Description Test Levels IEC 60068-2-1...

Table of Contents