Iii. Test Function For Er-A6In And Er-A5Rs - Sharp ER-A57R1 Service Manual

Table of Contents

Advertisement

III. TEST FUNCTION FOR ER-A6IN AND ER-A5RS

CHAPTER 1. General
This test program, is contained in the ER-A57R1 (option ROM), has
been developed for the purpose of confirming the operations of the
I/F board check conducted by the ER-A5RS and ER-A6IN mounted in
the ER-A570.
CHAPTER 2. Structure (RS-232 test
& inline test)
1 RS-232 test (RS-232 port test conducted by ER-A5RS
The following structure is required to execute RS-232 test pro-
gram.
ER-A570
ER-A5RS (I/F PWB Unit)
Loopback connector for testing (UKOG-6705 RCZZ)
ER-A57R1 (option control ROM)
ER-A570
+ ER-A57R1
Diagram of the loopback connector
1
2
3
4
CD
RD
TD
ER
2 Inline test
The following structure is required to execute the inline test pro-
gram.
ER-A570
ER-A6IN (inline I/F PWB unit)
ER-A57R1 (option control ROM)
Branch line (main line) cable (for transmission test)
Terminator (50Ω)
CHAPTER 3. Activation
This test program can be activated by inputting 3-digit number → TL
with the mode switch in the "SRV" position.
UKOG-6705RCZZ:
ER-A5RS: 2PCS
5
6
7
8
9
GND
DR
RS
CS
CI
CHAPTER 4. Test Job & Code
1 RS-232 I/F check
JOB & CODE
500
Channel check
501
RS-232 channel 1 check
502
RS-232 channel 2 check
503
RS-232 channel 3 check
504
RS-232 channel 4 check
505
RS-232 channel 5 check
506
RS-232 channel 6 check
507
RS-232 channel 7 check
2 Inline I/F check
JOB & CODE
600
IRC TEST 1
601
IRC TEST 2
602
IRC TEST 3
IRC
603
(SATELLITE setting)
IRC
604
(MASTER setting)
CHAPTER 5. Cautions
Options should be installed with the power supply turned off.
When setting the RS232C channels, avoid setting two or more
ports to the same channel. The ER-A570 allows installation of
max. two units of the ER-A5RS. In this case also, avoid setting two
ports of the ER-A5RS to the same channel. If not, the hardware
may be damaged.
Concerning the inspection items whose display formats are not
presented in this test function, nothing appears on the display
screen. (blank display)
CHAPTER 6. RS-232 Test
1. Channel check
1 Activation
The program is activated by JOB#500
SRV mode: 500 → TL
2 Contents to be tested
Information about connected RS-232 channel is printed.
Π ρ ιντινγ
διγιτ
21
20
ΧΗ7 ΧΗ6 ΧΗ5 ΧΗ4 ΧΗ3 ΧΗ2 ΧΗ1
CHn = 0 : Presence of channel
3 Confirmed content
Printed contents and the setting of channel changeover switch on
PWB are compared and confirmed.
3 ™ 1
Contents
Contents
TEST
4:
DATA
transmission
TEST
5:
DATA
transmission
19
18
17
16
15
1 : Ansence of channel
test
test
3 2 1
5 0 0