Auto Arm Pre-Alert; Senior Watch Time - Bosch solution 6000 Installation Manual

Hide thumbs Also See for solution 6000:
Table of Contents

Advertisement

Solution 6000
Installation Manual
The part entry time will start when any of the following
zone types area faulted and set to be monitored for Part
On or Part 2 On.
™ Burglary Delay 1
™ Burglary Delay 2
™ Burglary Instant
™ Burglary Inst No Exit
™ Burglary Handover
Only the installer or a master user can set the part entry
time for each area (001 to 255 seconds). Programming 001
seconds allows all non 24 hour burglary zones (including
delay zones) to act as if they were all instant zones when
the area is turned Part On or Part 2 On. Programming 000
seconds allows all non 24 hour burglary zones to operate
as they would if the area has been turned All On.
1) Press [MENU] + [2] + [8] + [3]. The keypad will
display a list of areas.
A1 Security System
A2 Area 2 Name
A3 Area 3 Name
Press  OK or MENU
2) Highlight the area required to change, then press
[OK] to select. The keypad will display the current
part entry time set for the area selected.
Part Entry Time A1
060 Seconds
Press 0-9 OK to SAVE
3) Using the numeric keys, enter the required entry
time in seconds. Valid times are 1 - 255 seconds, 0
= No exit time.
4) Press [OK] to save and exit or press [MENU] to exit
without saving.
Areas > Timers >

Auto Arm Pre-Alert

(*** System Wide Parameter ***)
This menu allows the installer to program the auto arm
pre-alert timer that is global for all areas. The auto arm
pre-alert timer can be programmed between 001 and 255
seconds / 000 = disabled.
For the auto arm pre-alert timer to operate, it requires at
least one area to follow a timezone. When the stop time
and day of the week programmed within a period of the
timezone has been met, the control panel will commence
the auto arm pre-alert time. When the auto arm pre-alert
time has expired, the area will automatically turn All On.
During the auto arm pre-alert time, the keypads assigned
6-10
Area Programming
MENU 2-8-4
0
1
0
Minutes
within the same area will sound a warning tone to alert
users that the area will soon automatically turn All On.
The auto arm pre-alert timer allows users the opportunity
to abort automatic arming for that set arming period, or
alternatively delay the area automatically turning All On
by 1 hour, by entering their PIN + [OFF] and then selecting
the option they require. If the user selects the option
to delay the auto arm, this sequence will repeat again
1 hour later untill the area is turned All On manually or
automatically.
To set up a timezone - see TimeZones.
1) Press [MENU] + [2] + [8] + [4]. The keypad will
display the current Pre-Alert Time.
Auto Arm Pre Alert
000 Minutes
Press 0-9 OK to SAVE
2) Using the numeric keys, enter the pre-alert time .
Valid times are 0 to 255 minutes. 0 = No Auto Arm
Pre Alert.
3) Press [OK] to save and exit or press [MENU] to exit
without saving.
Areas > Timers >

Senior Watch Time

(*** System Wide Parameter ***)
This feature can be used to verify that an elderly person
is OK or as a dead man timer for an onsite patrolman or
security officer.
This menu allows you to program the Senior Watch Time
period. The panel must register at least one burglary zone
in the programmed area to unseal and reseal during this
time period or the panel will report a Senior Watch alarm
to the base station.
A Senior Watch Restore will be sent when. at least one
zone is unsealed and resealed. Senior Watch monitoring
is only active when the corresponding area is in the
disarmed state.
1) Press [MENU] + [7] + [8] + [6]. The keypad will
display the current senior watch time. (default = 0
hours).
Senior Watch Time
000 Hours
Press 0-9 OK to SAVE
3) Using the numeric keys, enter the new senior watch
time. Valid times are 001 to 255 hours. 000 = No
Senior Watch Time.
MENU 2-8-6
0
Hours
2)
Bosch Security Systems 07/14 BLCC610I
0
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents