Auto Arm Pre Alert - Bosch solution 6000 Installation Manual

Hide thumbs Also See for solution 6000:
Table of Contents

Advertisement

Solution 6000
Installation Manual
If the event assignment for this output is set to zero (all
areas), then the output will operate as soon as any chime
zone is triggered provided that Chime Mode is on in
those areas. The output will reset when all Chime Zones
are resealed. For this event type to work Chime Mode
must be turned on. See MENU 2-0-5 — Chime On/Off
It also allows the output to reset when chime mode
i
is turned off by the user even if the chime zone is still
Note
faulted. It also allows if one or more chime zones
remain faulted after the one shot timer has expired,
the output programmed for chime will operate or
retrigger if another chime zone becomes faulted.
31 – Auto Arm Pre Alert
This event type will cause the output to operate when
the Auto Arm Pre-Alert Timer is active and will reset
when the Pre-Alert Timer expires or a valid user code is
entered.
The output will also reset when the auto arm pre-
i
alert time has been delayed by by the user .
Note
32 – Ready To Arm All On
This event type will cause the output to operate when
the area is disarmed and all zones in the area are sealled.
The output will reset when the area is armed or when a
zone becomes unsealed.
If the event assignment for this output is set to zero (all
areas), then the output will only operate if all areas are
disarmed and all zones are sealed. The output will reset if
any area is armed or if any zone becomes unsealed.
33 – Ready To Part Arm
This event type will cause the output to operate when
the area is disarmed and all zones in the area which are
to be monitored in Part On mode are sealed. The output
will reset when the area is armed or when a Part On zone
becomes unsealled.
If the event assignment for this output is set to zero (all
areas), then the output will only operate if all areas are
disarmed and all Part On zones are sealed. The output
will reset if any area is armed or if any Part On zone
becomes unsealed.
34 – Ready To Part 2 Arm
This event type will cause the output to operate when
the area is disarmed and all zones in the area which
are to be monitored in Part 2 On mode are sealled. The
output will reset when the area is armed or when a Part 2
On zone becomes unsealed.
If the event assignment for this output is set to zero (all
areas), then the output will only operate if all areas are
disarmed and all Part 2 On zones are sealed. The output
will reset if any area is armed or if any Part 2 On zone
becomes unsealed.
8-6
Output Programming
35 – Close Sent OK
This event type will cause the output to operate when
the Closing report has been acknowledged (Kissed-Off )
by the control room receiver. The output will reset when
the area is disarmed. If the output has been assigned to
multiple areas then it will only reset when all areas have
been disarmed.
36 – External Audible
This event type will cause the output to operate when
any audible alarm occurs. The output will reset when the
system or area is disarmed.
This event type will also generate speaker beeps
when the system or area is armed via a RF Keyfob, the
Programmable Input Terminal or Keyswitch zone.
™ 1 beep when the area is disarmed
™ 2 beeps when the area is armed All On
™ 3 beeps when the area is armed Part On
37 – Internal Audible
This event type will cause the output to operate when
any audible alarm occurs. The output will reset when
the system or area is disarmed. No speaker beeps are
generated for this event type.
38 – Any Zone Alarm
This event type will cause the output to operate when
any silent or audible alarm occurs. The output will reset
when the system or area is disarmed.
39 – Fire Alarm
This event type will cause the output to operate when
any audible fire zone or keypad emergency fire alarm
occurs. The output will reset when the system or area is
disarmed.
40 – Burglary Alarm
This event type will cause the output to operate when
any audible burglary alarm (including keypad emergency
panic, medical and tamper alarm) occurs. The output will
reset when the system or area is disarmed.
41 – Silent Alarm
This event type will cause the output to operate when
any silent alarm occurs (including silent fire and silent
keypad emergency alarms). The output will reset when
the system or area is disarmed.
42 – Duress Alarm
This event type will cause the output to operate when a
user initiates a Duress alarm.
43 – Keypad Medical
This event type will cause the output to operate when a
silent or audible medical alarm has been initiated from
the keypad. The output will reset when the system or
area is disarmed.
Bosch Security Systems 07/14 BLCC610I