Set-Up - Bosch GE-50576-A Operating Manual

Belt tension tester
Table of Contents

Advertisement

5.0 SET-UP

1. To go to the set-up menu, touch the icon on
the right
2. The Set-up menu includes two settings,
min/max value and touch screen
re-calibration.
The first button
the tested frequency limits. The min/max
threshold can be adjusted from 100~500 Hz
by touching the left/right. A single touch
will move +/- 1 increment, and holding the
arrow will move +/- 5 increments.
When the desired values are displayed,
touch the center button
these settings. A tone will sound to indicate
a successful save. Touch the right button
to return to the default setting.
Touch, the left button
the previous menu,
To re-calibrate the touch screen, touch the
second button on the set-up screen
When a "+" symbol appears on the
display, press the center of the "+". After
5 steps for each corner and the center, the
display will return to the set-up menu.
WARNING!
GE-50576 units are calibrated before shipment. They do not require recalibration unless
the touch screen is not working properly (mis-aligned). If recalibration is needed use a
small firm-pointed device such as an ink-pen rather than the stylus pen this is included
with the tool (GE-50576- 04). This pen is soft pointed and will not re-calibrate properly.
.
allows adjustment of
to save
to return to
.
– 7 –