6.3

Status and Monitoring Page

Table Element
Hi-Q number
Hi-Q Type
Hi-Q Status
Hi-Q Input Number
Allegiant Logical Camera Number
Camera Status
BUTTON: Switch video from selected
Primary Hi-Q to a Backup Hi-Q
BUTTON: Set Selected Backup Hi-Q
to "Available"
BUTTON: Silence Beep
BUTTON: Add Manual Event Message
ADIM Messages
BUTTON: Open Log File
Allegiant On-line
Explained
Fixed field depending on where the Hi-Q
is entered into the table
Determines configuration of the Hi-Q in the
system
Indicates operational status of a Hi-Q:
On-Line and operational (Green);
Off-Line (Red);
Back-up unit that is currently backing up
a primary Hi-Q (Yellow)
Physical inputs on the Hi-Q.
If a Backup Hi-Q is Backing up a Primary Hi-Q, this
field indicates the logical camera numbers that are
being recorded by the backup Hi-Qs. For Primary
Hi-Qs, this is simply the logical camera attached to
the Hi-Q.
Field is gray when the associated Hi-Q is
Off-Line, or if the Hi-Q is a Backup Hi-Q in the
Available state.
This can be used to perform maintenance or repair
on a Hi-Q without loosing any recording. To
manually switch cameras to backup Hi-Q, first
select a Hi-Q, then press this button.
Frees up a Backup DVR that's currently in use.
This DVR can subsequently be used to backup
another DVR. First, ensure that the primary Hi-Q
is operating and On-Line, then select the Backup
Hi-Q and press this button.
Silences the ADIM PC alarm (beep).
Allows a user to manually add a message to the
Event Log.
Displays the most recent information, warning,
and error events.
The Open File dialog box is displayed.
The log file names indicate the day.
(See Figures 6.1a & 6.1b)
The lower right-hand corner of the screen
indicates On/Off-Line status of the Allegiant.
15
Field Values
1 - 800
Primary, Backup, Review Monitor
(See Appendix E for more details)
Primary:
On-Line (Green),
Off-Line (Red)
Backup:
Available (Green), Backing up a
Primary Hi-Q (Yellow)
1 through 4
1- 9,999
OK (green)
NO Sync (red)
Green = On-Line
Red = Off-Line