Be sure to disconnect the power plug from the
power outlet. Merely turning off the power switch
will not cut the power.
4) Replace the DC controller PCB.
5) Turn on the power switch.
6) Initialize the RAM on the DC controller PCB. (See
the appropriate instructions.)
7) Turn on and then off the power switch.
2.7.4 Initializing the RAM
on the DC controller PCB
CLC5100 / CLC4000
1) Record the setting of 'OFFSET C/M/Y/K' found in
the second row of page 2 on the EPC screen of
'FUCNT' in service mode.
2) Start service mode, and check to make sure that
'BELT POS' of 'BLT DRFT' under 'DISP' is
'CENTER'; if not, move the transfer belt to the
center.
3) Execute 'FUNC>DC CON>RAM LR' in service
mode.
4) Turn off the power switch, and disconnect and then
connect the power plug (so that the RAM will be
cleared).
5) Turn on the power switch.
6) If you have replaced the DC controller PCB,
replace the developer according to the instructions
on Replacing the Developer.
7) Enter the value of A recorded on the service label.
(If you have changed other service mode settings
related to the DC controller, enter such settings as
well.)
8) Execute 'REG APER' of 'INSTALL2' under
'FUNC' in service mode.
9) Enter the setting of 'OFFSET C/M/Y/K' recorded
in step 1) to the following: 'FUNC>DC
CON>POTOFST C/M/Y/K'.
The settings on the screens of service mode are
cleared when the RAM on the reader controller PCB
is initialized.
0002-5879
The settings on the screens of service mode are
cleared when the RAM on the DC controller PCB is
initialized.
Service Mode Settings Related to the DC Controller
PCB
T-2-4
ADJUST
Settings on ADJ XY screen
Settings on DOC REC screen
Settings on PROJ screen
Settings on ED/RF screen
Settings on COL ADJ screen
Settings on ADJ MISC screen
Settings on PRJ ADJ screen
OPTION
Settings on P OPT screen
Settings on ON SET on P OPT
screen
Settings on REMOTE screen
Settings on DECK screen
T-2-5
ADJUST
Settings on PASCAL screen
Settings on FEED ADJ
screen
Settings on ENV SET screen
Settings on HV TR C/M/Y/K
screen
Settings on HV SP screen
Settings on HV FS screen
Settings on HV EL screen
FUNC
Settings on DC CON screen
Settings on P UP TMG
screen
Settings on P THICK screen
Settings on IMG REG screen
Settings on FUSER screen
OPTION
Settings on P OPT screen
(except ON SET))
Chapter 2
2-27

Advertisement

Table of Contents
loading

Table of Contents