Issue 10/03
lin
rot
Fig. 3-65
Using this data, MICROMASTER 440 calculates the ratio between the distance
and the motor revolutions and can therefore consider the movement on the load
side.
NOTE
When the positioning down ramp is enabled using parameter P0500 = 3, then
implicitly the control mode P1300 is reset as follows as a function of parameter
P0205:
a) P0205 = 0
b) P0205 = 1
This change can be undone again after the positioning down ramp has been
enabled by modifying parameter P1300.
MICROMASTER 440
Operating Instructions
6SE6400-5AW00-0BP0
Disposition
Load
Motor
Gear
Ü
n
n
Motor
Load
Motor
Gear
Ü
n
n
Motor
Load
Rotary or linear axis
P1300 = 0
P1300 = 2
s
lin
Motor revolutions
Ü =
Load revolutions
z
z = screw lead =
Motor revolutions
s
Ü =
rot
Load revolutions
3 Functions
Parameter
P2481
=
P2482
No. of revolutions
= P2484
1 [unit]
P2481
=
P2482
153