Low Flame Adjustment - KitchenAid KFGR270LSS Technical Education

Table of Contents

Advertisement

GAS HOOKUP & LEAK CHECK
1.
For Natural Gas: Connect a certified 1/2"
gas supply pipe to the inlet side of the
regulator from a natural gas supply, ac-
cording to local codes requirements. Use
a pipe thread sealant that is certified for
use with natural gas at connections, where
required.
2.
For L.P. Gas: Connect the regulator hose
connector to a full 20# L.P. tank, and
hand-tighten it.
3.
Turn on the gas supply to the grill.
4.
Test all of the connections by brushing on
an approved noncorrosive leak-detection
solution. Bubbles will indicate a leak. Cor-
rect any leaks found.
ADJUSTING THE AIR SHUTTERS
1.
Light the grill using information in "Lighting
The Grill" on page 3-3.
2.
Observe the flame to determine which
burners need adjustment, and how the
flame is acting.
3.
Turn off the valve and wait until the grill
and burners are cool.
4.
Remove the grill grates and sear plates.
5.
Remove the burner and loosen the air
shutter adjustment screw.
a) If the flame is yellow (not enough air),
turn the air shutter counterclockwise.
b) If the flame is noisy, or lifts away from
the burner (too much air), turn the air
shutter clockwise.
Adjustment should be from 1/8" to 1/4".
6.
Tighten the air shutter adjustment screw.
Air Shutter Screw
7.
Replace the burner sear plates and grates.
8.
Ignite the burners and check the flames.
9.
Repeat Steps 1 through 8, if needed. Only
adjust the burners that need adjustment.

LOW FLAME ADJUSTMENT

If the flame goes out on the "LO" setting, the low
flame setting must be adjusted.
1.
Turn off the valve and wait until the grill
and burners are cool.
2.
Remove the grill grates and sear plates.
3.
Light the grill using the information in "Light-
ing The Grill" on page 3-3.
4.
Turn the burner to its lowest setting and
remove the knob.
5.
Hold the valve stem with pliers and insert
a thin flat-blade screwdriver into the shaft.
Valve Stem
6.
Watch the flame and slowly turn the screw-
driver counterclockwise.
7.
Adjust the flame to a minimum stable
flame.
8.
Replace the control knob and turn off the
burner.
9.
Repeat Steps 3 through 8 for each burner,
if needed.
10. Replace the sear plates and grates after
the burners have cooled.
2-12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents