Panasonic KX-HDV430 Administrator's Manual page 182

Hide thumbs Also See for KX-HDV430:
Table of Contents

Advertisement

5.3.5 Provisioning Settings
CFG_CYCLIC
Value Format
Description
Value Range
Default Value
Web User Interface Reference
CFG_CYCLIC_INTVL
Value Format
Description
Value Range
Default Value
Web User Interface Reference
CFG_RESYNC_TIME
Value Format
Description
Value Range
Default Value
Web User Interface Reference
CFG_RTRY_INTVL
Value Format
Description
Value Range
182
Administrator Guide
BOOLEAN
Specifies whether the unit periodically checks for updates of
configuration files.
Y: Enable periodic synchronization
N: Disable
N
Cyclic Auto Resync
INTEGER
Specifies the interval, in minutes, between periodic checks for
updates of the configuration files.
1–40320
10080
Resync Interval
STRING
Specifies the time (hour:minute) that the unit checks for updates of
configuration files.
00:00–23:59
Note
If the value for this setting is any valid value other than an
empty string, the unit downloads the configuration files at the
fixed time, and the settings specified in "CFG_CYCLIC",
"CFG_CYCLIC_INTVL", and "CFG_RTRY_INTVL" are disabled.
If the value for this setting is an empty string, downloading the
configuration files at the fixed time are disabled.
Empty string
Time Resync
INTEGER
Specifies the period of time, in minutes, that the unit will retry
checking for an update of the configuration files after a configuration
file access error has occurred.
Note
This setting is available only when "CFG_CYCLIC" is set to "Y".
1–1440
Document Version 2016-05