Step 1.
Select [Common] → [Controller Setting] from the menu.
Step 2.
The Controller Setting window is displayed. Select the channel to be used from the list menu.
Step 3.
Set Manufacturer, Controller Type, I/F, and Driver according to the connected equipment to be used.
Step 4.
The detailed setting is displayed after Manufacturer, Controller Type, I/F, and Driver are set.
Make the settings according to the usage environment.
Click the [OK] button when settings are completed.
13.4 Precautions
For cautions or troubleshooting of the GOT Mobile function, refer to the following manual.
➠
GT Designer3 (GOT2000) Screen Design Manual
POINT
POINT
POINT
Ethernet-based driver
For using the GOT Mobile function, any of the following Ethernet communication drivers must be
set on the GOT.
• Gateway
• Ethernet Download
• Ethernet (MELSEC), Q17nNC, CRnD-700, Gateway
• Ethernet (FX), Gateway
• Ethernet (OMRON), Gateway
• Ethernet (KEYENCE), Gateway
• Ethernet (TOSHIBA nv), Gateway
• Ethernet (FUJI), Gateway
• Ethernet (YASKAWA), Gateway
• Ethernet (YASKAWA MP3000), Gateway
• Ethernet (YOKOGAWA), Gateway
• EtherNet/IP (AB), Gateway
• EtherNet/IP (AB Tag), Gateway
• Ethernet (SIEMENS S7), Gateway
• Ethernet (SIEMENS OP), Gateway
• Ethernet (SLMP), Gateway
• MODBUS/TCP, Gateway
• Ethernet (MICROCOMPUTER)
In the peripheral setting, set [Destination I/F] in [Ethernet Download] for the [PC (Data Transfer)]
dialog box.
To connect controllers including a programmable controller to the GOT by using the Ethernet
connection, no setting is required.
For the details of [Ethernet Download] , refer to the following
➠
GT Designer3 (GOT2000) Screen Design Manual