GE 350 Communications Manual page 597

Protective relay platform
Hide thumbs Also See for 350:
Table of Contents

Advertisement

CHAPTER 12: 350 MODBUS MEMORY MAP AND FORMAT CODES
Modbus
Hex
Description
Address
Address
46844
0x1ABB
Directional Power 2 Pickup
Delay
46845
0x1ABC
Directional Power 2 Output
Relays 3-6
46859
0x1ACA
Broken Conductor Function
46860
0x1ACB
Broken Conductor I_2/I_1
Ratio
46861
0x1ACC
Broken Conductor I_1 Min
46862
0x1ACD
Broken Conductor I_1 Max
46863
0x1ACE
Broken Conductor Pickup
Delay
46864
0x1ACF
Broken Conductor Output
Relays 3-6
46933
0x1B14
Negative Seq OV 2 Function 0
46934
0x1B15
Negative Seq OV 2 Pkp
46935
0x1B16
Negative Seq OV 2 Delay
46940
0x1B1B
Auxiliary UV 2 Function
46941
0x1B1C
Auxiliary UV 2 Pickup
46942
0x1B1D
Auxiliary UV 2 Curve
46943
0x1B1E
Auxiliary UV 2 Delay
46948
0x1B23
Aux UV2 Min Voltage
46949
0x1B24
Neutral OV 2 Function
46950
0x1B25
Neutral OV 2 Pickup
46951
0x1B26
Neutral OV 2 Delay
46956
0x1B2B
Neutral OV 3 Function
46957
0x1B2C
Neutral OV 3 Pickup
46958
0x1B2D
Neutral OV 3 Delay
46963
0x1B32
Neutral OV 4 Function
46964
0x1B33
Neutral OV 4 Pickup
46965
0x1B34
Neutral OV 4 Delay
46970
0x1B39
Overfrequency 3 Function
46971
0x1B3A
Overfrequency 3 Pickup
46972
0x1B3B
Overfrequency 3 Delay
46977
0x1B40
Overfrequency 4 Function
46978
0x1B41
Overfrequency 4 Pickup
46979
0x1B42
Overfrequency 4 Delay
47143
0x1BE6
Underfrequency 3 Function
47144
0x1BE7
Underfrequency 3 Pkp
47145
0x1BE8
Underfrequency 3 Delay
47146
0x1BE9
Minimum UF Voltage 3
47151
0x1BEE
Underfrequency 4 Function
47152
0x1BEF
Underfrequency 4 Pkp
47153
0x1BF0
Underfrequency 4 Delay
47154
0x1BF1
Minimum UF Voltage 4
PROTECTION FUNCTION BLOCKING
40205
0xCC
Volts Per Hertz Block 1
40206
0xCD
Volts Per Hertz Block 2
40207
0xCE
Volts Per Hertz Block 3
SR3 SERIES PROTECTIVE RELAY PLATFORM – COMMUNICATIONS GUIDE
Min
Max
0
6000
0
0x3F
0
4
200
1000
5
100
5
500
0
60000
0
0x3F
3
0
125
0
60000
0
3
0
125
0
1
0
60000
0
125
0
3
0
125
0
60000
0
3
0
125
0
60000
0
3
0
125
0
60000
0
3
4000
7000
10
60000
0
3
4000
7000
10
60000
0
3
4000
7000
10
60000
0
125
0
3
4000
7000
10
60000
0
125
0
0xEF02
0
0xEF02
0
0xEF02
350 MODBUS MEMORY MAP
Step Units
Format
Factory
Code
Default
1
s
F2
5
1
---
FC198
0
1
---
FC205
0
1
%
F2
200
1
x CT
F3
10
1
x CT
F3
150
1
s
F17A
20000
1
---
FC198
0
1
---
FC197
0
1
x VT
F3
30
1
s
F3
200
1
---
FC197
0
1
x VT
F3
75
1
---
F93
1
1
s
F3
200
1
x VT
F3
30
1
---
FC197
0
1
x VT
F3
30
1
s
F3
200
1
---
FC197
0
1
x VT
F3
30
1
s
F3
200
1
---
FC197
0
1
x VT
F3
30
1
s
F3
200
1
---
FC197
0
1
Hz
F3
6050
1
s
F3
200
1
---
FC197
0
1
Hz
F3
6050
1
s
F3
200
1
---
FC197
0
1
Hz
F3
5900
1
s
F3
200
1
x VT
F3
70
1
---
FC197
0
1
Hz
F3
5900
1
s
F3
200
1
x VT
F3
70
1
---
F89
0
1
---
F89
0
1
---
F89
0
Size in
words
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
12-79

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

339345