Hitachi CP-X2511N Service Manual page 17

Hide thumbs Also See for CP-X2511N:
Table of Contents

Advertisement

CP-X2511N(C15I-25N2) / CP-X3011N(C15I-30N2) / CP-X4011N(C15I-40N2) / CP-X2011N(C15-20N2) / ED-X45N(C15-20N2)
Time is not correctly displayed.
DATE
AND TIME is
NO
displayed as 2000/1/1 0:00
in INFORMATION on
NETWORK
menu.
YES
NO
Was the time set before?
YES
YES
Is internal clock battery
old ?
NO
Is voltage
input at pin 1 of
NO
EE02 on PWB assembly
MAIN when power switch
was turned
off.
YES
2.5V or more
PWB assembly
MAIN
Set the time in
DATE AND TIME on
NETWORK menu.
Use new battery.
(see 6.4)
• PWB assembly BATTERY
• Cables (CNBAT)
17
Is TIME
NO
DIFFERENCE on
INFORMATION correct ?
YES
Is the
NO
time adjusted by
Daylight Savings Time ?
YES
PWB assembly
MAIN
Set the time.
Configure the Daylight
Saving Time in web
setting.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp-x3011nEd-x45nCp-x4011nCp-x2011n

Table of Contents