■ Detach and attach the upper case.
Follow the procedure below to detach and attach the upper case.
When disassembling
a. Remove the Lamp door.
The lamp door must be removed before the upper case when disassembling the machine. If the upper
case is detached with the lamp door installed, the MAIN board might be damaged.
b. Remove 8 screws on the bottom and 2 screws on the rear to detach the upper case.
This is not a screw hole. Do NOT insert a screw or screwdriver into it to avoid damaging the inside.
2 screws
CAUTION
Lamp door
Loosen this screw
CAUTION
8 screws