11.2

Summary of basic and alarm program features

Features
Alarm program 1
Devices
Cameras1 to 48
Camera head controls 1 to 48
Monitors 1 to 4
Keyboards 1 to 4
IVM-NT operating stations 1 to 3
TELEMAT
Basic functions (available without alarm processing)
Central dial-up using keyboard 1
Decentral dial-up using keyboards 2, 3 and 4
Monitor sequencing on monitors 1 to 4
Camera label on all monitors
Date, time on a maximum of 8 monitors
Camera breakdown signal on all monitors
48 cameras via a single operating
Camera and lens control using
station
CDCs
Camera position control per CDC
Alarm processing functions
Detector groups per camera
Detector groups input configuration configured for external detector
groups(48)
2
Max. no. of alarm images
(simultaneous display)
2
Max. no. of alarm events
(simultaneous display)
Neighbouring camera display no
Alarm image display alarm image 1 on monitor 1
alarm image 2 on monitor 2
.
in turn on monitors 1 and 2
Most recent alarm image display
(transfer/serial switching)
serial switching
Switching method
(transfer/serial switching)
no
New alarm images overwrite older
images
yes
Mandatory alarm image
on monitors 1 and 2
acknowledgement
next image on first free monitor
Alarm image sequence all as yet unacknowledged alarm
images on monitor 4
Factory settings
Deviation from the factory setting
Siemens Building Technologies
Fire Safety & Security Products
Alarm program 2
Alarm program 4
Factory setting
1 to 48
1 to 48
1 to 48
1 to 48
1 to 4
1 to 4
1 to 4
1 to 4
1 to 3
1 to 3
using keyboard 1
using keyboard 1
using keyboards 2, 3 and 4
using keyboards 2, 3 and 4
on monitors 1 to 4
on monitors 1 to 4
on all monitors
on all monitors
on a maximum of 8 monitors
on a maximum of 8 monitors
on all monitors
on all monitors
48 cameras via a single operating
48 cameras via a single
station
operating station
pro CDC
pro CDC
per camera
per camera
configured for external detector
configured for external detector
groups(48)
groups(48)
2
2
2
1
no
yes
monitor 2
alarm image 1 on monitor 1
alarm image 1 on monitor 1
alarm image 2 on monitor 2
and, until acknowledged, on
alarm image 3 on monitor 1 etc.
monitor 4.
in turn on monitors 1 and 2
both images simultaneously on
monitor 1 and monitor 2
serial switching
serial switching
yes
no
yes
yes
on monitors 1 and 2
on monitor 1
next image on first free monitor
monitor 2 (neighbouring
camera) is also released
all as yet unacknowledged alarm
all as yet unacknowledged
images on monitor 4
alarm images on monitor 4
Alarm program 5
Alarm program 3
1 to 48
1 to 48
1 to 48
1 to 48
1 to 4
1 to 4
1 to 4
1 to 4
1 to 3
not recommended for IVM-NT
not recommended for TELEMAT
using keyboard 1
using keyboard 1
using keyboards 2, 3 and 4
using keyboards 2, 3 and 4
on monitors 1 to 4
on monitors 1 to 4
on all monitors
on all monitors
on a maximum of 8 monitors
on a maximum of 8 monitors
on all monitors
on all monitors
48 cameras via a single
48 cameras via a single operating
operating station
station
pro CDC
pro CDC
per camera
per camera
configured for external
configured for external detector
detector groups(48)
groups(48)
1
4
1
4
yes
no
monitor 2
alarm image 1 on monitor 1
most recent alarm image (highest
number) on monitor 1
next most recent on monitors 2 to 4
both images simultaneously
last in first out (LIFO)
on monitor 1 and monitor 2
on monitor 1
previous image on monitor 3
serial switching
transfer switching
yes
yes
yes
no
on monitor 1
monitor 2 (neighbouring
camera) is also released
all as yet unacknowledged
no
alarm images on monitor 4
06.20013
Appendix
Alarm program 6
1 to 48
1 to 48
1 to 4
1 to 4
not recommended for IVM-
NT
not recommended for
TELEMAT
using keyboard 1
using keyboards 2, 3 and 4
on monitors 1 to 4
on all monitors
on a maximum of 8 monitors
on all monitors
48 cameras via a single
operating station
pro CDC
per camera
configured for external
detector groups(48)
2
4
yes
monitor 2
monitor 4
most recent alarm image 1
on monitor 1
alarm image 2 on monitor 3
last in first out (LIFO)
most recent on monitor 1
previous image on monitor 3
transfer switching
yes
no
no
47