The TH192 DN and TH192 DNV thermostats are
proportional single output, dual set point, 2-pipe or 3-pipe
(high air capacity) temperature controllers. Each TH192
DN and DNV chassis includes a wall plate for thermostat
installation in a variety of rough-in installation kits.
P P P P r r r r o o o o d d d d u u u u c c c c t t t t N N N N u u u u m m m m b b b b e e e e r r r r s s s s
TH192 DN and TH192 DNV
P P P P r r r r e e e e r r r r equ
equis is is isi i i i t t t t e e e e s s s s
equ
equ
Review all instructions before beginning
installation.
Verify job drawings are available to reference
specific job site information as needed.
Verify rough-in installation kits (wall-box or tubing
runs) are pre-installed.
E E E E x x x x pe
pec c c c t t t t e e e e d d d d I I I I n n n n s s s s t t t t a a a a ll ll ll lla a a a t t t t i i i i o o o o n n n n T T T T i i i i m m m m e e e e
pe
pe
30 Minutes
R R R R equ
equi i i i r r r r ed
equ
equ
ed T T T T oo
ed
ed
ools ls ls ls
oo
oo
Medium flat blade screwdriver
Needle nose pliers
Small level
Calibration and Cover Screw Wrench or 1/16"
Allen wrench (192-632)
Needle Probe with 1-1/2" diameter, 0 to 30 psig
(0 to 200 kPa) test gauge (192-633)
I I I I n n n n s s s s t t t t a a a a ll ll ll lla a a a t t t t i i i i on
on C C C C o o o o n n n n v v v v e e e e n n n n t t t t i i i i on
on
on
W W W W AR
ARN N N N I I I I NG
AR
AR
NG
NG
NG
CA
CA
CAU U U U T T T T IO
CA
IO IO
ION N N N
ons s s s
on
on
Personal injury/loss of life may
occur if a procedure is not
performed as specified.
Equipment damage, or loss of
data may occur if the user
does not follow procedure as
specified.
I I I I n n n n s s s s t t t t a a a a ll ll ll lla a a a t t t t i i i i on
on
on
on
O O O O v v v v e e e e r r r r v v v v i i i i e e e e w w w w
The TH192 DN/DNV thermostat and wall plate mount
vertically to a wall using a variety of rough-in installation
kits (for example, wall box kits or tubing terminal kits). The
ends of the air lines from the rough-in installation kits have
terminal adapters that snap into the wall plate. Terminal
adapters also are available separately as orderable
accessories. (Note that certain retrofit applications allow
air connections directly to the thermostat chassis).
The "S", "R1", and "R2" labels on both the thermostat
chassis and the wall plate identify the air line connections.
The thermostat plugs into the terminal adapters on the
wall plate. The Piping section of this document shows
typical connections.
Two cover screws plus latch arms on the wall plate hold
the thermostat in place. The cover fits over the thermostat
and the two cover screws fasten it to the wall plate.
P P P P r r r r o o o o c c c c e e e e d d d d u u u u r r r r e e e e
The following procedure is for a typical thermostat
installation and assumes the rough-in installation kit is in
place. See Figure 1.
1.
The rough-in installation kit provides a supply (blue) air
line and a return air line joined by an air link. Remove
the terminal adapters from the air link and snap them
into the wall plate at their respective locations.
2.
Using the mounting screws supplied with the
thermostat chassis, install the wall plate on the wall
as follows:
a.
Guide the screws through the slotted key holes
on the wall plate and partially insert them into
wall.
b.
Orient the wall plate so that it is square and level.
c.
Tighten the mounting screws to secure the wall
plate in place.
3.
Moisten the thermostat supply and return ports to
lubricate them. Carefully insert the thermostat ports
into the terminal adapter "O" rings on the wall plate.
I I I I n n n n s s s s t t t t a a a a ll ll ll lla a a a t t t t i i i i on on on on I I I I n n n n s s s s t t t t r r r r u u u u c c c c t t t t i i i i on on on ons s s s
Document No. 129-077
Rev. 2, November, 1999
P P P P a a a a ge
ge 1 1 1 1 o o o o f f f f 4 4 4 4
ge
ge

Advertisement

loading

Summary of Contents for Siemens TH192 DN

  • Page 1 I I I I n n n n s s s s t t t t a a a a ll ll ll lla a a a t t t t i i i i on The TH192 DN and TH192 DNV thermostats are...
  • Page 2 P P P P a a a a ge ge 2 2 2 2 o o o o f f f f 4 4 4 4 Siemens Building Technologies, Inc.
  • Page 3 One turn increases the • For TH192 DN and DNV thermostats, the test port is changeover point by about 3 psi (20 kPa). Turn on on the left side. the supply pressure and recheck to verify the new changeover point.
  • Page 4 Allow the thermostat to stand for about five minutes to • adjust to the new setting. For TH192 DN and DNV thermostats, the port is on the left side. Moisten the needle and insert the test gauge and needle adapter in the test port (Figure 5). Read the...

This manual is also suitable for:

Th192 dnv