Panasonic KX-TDA100 Installation Manual page 120

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA100:
Table of Contents

Advertisement

2.8 Connection of DECT Portable Stations
CAUTION
The CS should be kept free of dust, moisture, high temperature (more than 40 °C),
low temperature (less than 0 °C), vibration, and should not be exposed to direct
sunlight.
The CS should not be placed outdoors (use indoors).
The CS should not be placed near high voltage equipment.
The CS should not be placed on a metal object.
Do not use this wireless system near another high power cordless system such as
DECT or SS wireless.
Keep distance between the equipment listed below in order to prevent noise,
interference or the disconnection of a conversation. (The distance may vary
depending on the environment.)
Too many CSs in a small area can cause problems due to conflicts over which signal
channels each CS can use. Ideally, CSs should be a minimum of 25 m to 40 m apart.
However, the required distance between CSs may vary depending on the
environment of the installation site and conditions in which the wireless system is
used. Conduct the site survey to determine the appropriate distance.
120
Installation Manual
Equipment
CS and office equipment such as a computer, telex,
fax machine, etc., or microwaves
CS and PS
Each PS
Hybrid IP-PBX and CS
Distance
More than 2 m
More than 1 m
More than 0.5 m
More than 2 m