X3
Error reset
Y13
X3
This section describes a sample sequence program to acquire error information.
FROMP
H1B1
D500
H0
D500
WANDP
H0FF
MOVP
D500
SFRP
D502
7
9
MELSEC-A
K1
Read error information
D501
Station number generating
error
D502
Error information
K8
Error code
SET
Y13
Set error reset request
RST
Y13
Reset error reset request