the outdoor should all satisfy the requirements for surge immunity. The indices are
shown in Table B-7.
Table B-7 Surge immunity indices
AC port
Control line, signal line
Control line, signal line (outdoors)
Note:
The test method complies with IEC61000-4-5 [11].
VI. Common-mode fast transient pulse immunity
The signal & data line between CDMA cabinets and that connected with other systems
(such as E1 trunk line), control line and cable connected to DC input/output port, should
satisfy the requirements for fast transient pulse immunity. The indices are shown in
Table B-8.
Table B-8 Common-mode fast transient pulse immunity indices
Signal control line port
DC line input/output port
AC line input port
Port
Line~line, 2kV
Line~ground, 4kV
Line~line, 0.5kV
Line~ground, 1kV
Line~line, 1kV
Line~ground, 2kV
Port
B-4
Appendix B EMC Performance
Level
Level
0.5kV
1kV
2kV
System Principle
Performance class
B
B
B
Performance class
B
B
B