Disassembling The Old Thermostat Head - Silvercrest RT2000 BT Operating Manual

Programmable radiator thermostat bluetooth
Table of Contents

Advertisement

The union nut (15) permanently attached to the de-
vice fi ts on all radiator valves with thread size M30
x 1.5 mm of the most common manufacturers, e.g.
Heimeier, MNG, Junkers, Landis&Gyr (Duodyr), Hon-
eywell-Braukmann, Oventrop type A, Oventrop AV6,
Schlösser, Comap D805, Valf, Sanayii, Mertik Max-
itrol, Watts, Wingenroth (Wirofl ex) R.B.M, Tiemme,
Jaga, Siemens, Idmar.
The adapters contained in the supply package ena-
ble the device to be fi tted to Danfoss RA-, Danfoss
RAV and Danfoss RAVL radiator valves.

Disassembling the Old Thermostat Head

1. Set the thermostat head (11) to the temperature
range  (or position 5).
This means the thermostat head is no longer pressing
on the spindle of the radiator valve and can be re-
moved more easily.
2. Unscrew the fi xing element (9) of the thermostat
head and remove the thermostat head.