The union nut (15) permanently attached to the de-
vice fi ts on all radiator valves with thread size M30
x 1.5 mm of the most common manufacturers, e.g.
Heimeier, MNG, Junkers, Landis&Gyr (Duodyr), Hon-
eywell-Braukmann, Oventrop type A, Oventrop AV6,
Schlösser, Comap D805, Valf, Sanayii, Mertik Max-
itrol, Watts, Wingenroth (Wirofl ex) R.B.M, Tiemme,
Jaga, Siemens, Idmar.
The adapters contained in the supply package ena-
ble the device to be fi tted to Danfoss RA-, Danfoss
RAV and Danfoss RAVL radiator valves.
Disassembling the Old Thermostat Head
1. Set the thermostat head (11) to the temperature
range (or position 5).
This means the thermostat head is no longer pressing
on the spindle of the radiator valve and can be re-
moved more easily.
2. Unscrew the fi xing element (9) of the thermostat
head and remove the thermostat head.
18