GE L30 Instruction Manual page 539

Line current differential system, ur series
Hide thumbs Also See for L30:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 57 of 57)
ADDR
REGISTER NAME
D402
PMU 1 STN
D40A
PMU 1 Source
D40B
PMU 1 Class
D40C
PMU 1 Format
D40D
PMU 1 Style
D40E
PMU 1 Rate
D40F
PMU 1 PHS-x (14 items)
D41D
PMU 1 PHS-x Name (14 items)
D48D
PMU 1 A-CH-x (16 items)
D49D
PMU 1 A-CH-x (16 items)
D51D
PMU 1 D-CH-x (16 items)
D52D
PMU 1 D-CH-x Name (16 items)
D5AD
PMU 1 D-CH-x Normal State (16 items)
D5BD
PMU 1 Reserved (16 items)
Phasor Measurement Unit Aggregator (Read/Write Setting)
DB38
Aggregator 1 IDcode
DB39
Aggregator 1 Protocol
DB3A
Aggregator 1 TCP Port
DB3B
Aggregator 1 UDP Port
DB3C
PMU Aggregator 1 PDC Network Control
DB3D
Aggregator 1 Include PMU1
DB41
PMU Aggregator 1 Reserved (8 items)
Phasor Measurement Unit Recording Command (Read/Write Command)
E4D4
PMU 1 Recording Clear Command
E4D5
PMU 1 Recording Force Trigger
Phasor Measurement Unit Recording (Read/Write Setting)
E4DC
PMU 1 Record Function
E4DD
PMU 1 No of Timed Records
E4DE
PMU 1 Trigger Mode
E4DF
PMU 1 Timed Trigger Position
Phasor Measurement Unit Frequency Trigger (Read/Write Setting)
ECCC
PMU 1 Frequency Trigger Function
ECCD
PMU 1 Frequency Trigger Low Frequency
ECCE
PMU 1 Frequency Trigger High Frequency
ECCF
PMU 1 Frequency Trigger Pickup Time
ECD0
PMU 1 Frequency Trigger Dropout Time
ECD1
PMU 1 Frequency Trigger Block (3 items)
ECD4
PMU 1 Frequency Trigger Target
ECD5
PMU 1 Frequency Trigger Events
Settings File Template (Read/Write Setting)
ED00
FlexLogic™ Displays Active
ED01
Reserved (6 items)
Setting File Template (Read Only Non-Volatile)
ED07
Last Settings Change Date
Settings File Template (Read/Write Setting)
ED09
Template Bitmask (750 items)
Phasor Measurement Unit Records (Read Only)
EFFF
PMU Recording Number of Triggers
GE Multilin
RANGE
---
0 to 5
0 to 2
0 to 1
0 to 1
0 to 13
0 to 14
---
0 to 65535
---
0 to 65535
---
0 to 1
0 to 1
1 to 65534
0 to 1
1 to 65534
1 to 65534
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
2 to 128
0 to 1
1 to 50
0 to 1
20 to 70
20 to 70
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
---
0 to 4294967295
0 to 65535
0 to 65535
L30 Line Current Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
---
F203
---
1
F167
---
1
F549
---
1
F547
---
1
F546
---
1
F544
---
1
F543
---
---
F203
"GE-UR-PMU-PHS 1 "
---
1
F600
---
---
F203
"AnalogChannel 1 "
---
1
F300
---
---
F203
---
1
F108
---
1
F001
---
1
F001
---
1
F548
---
1
F001
---
1
F001
---
1
F102
---
1
F126
---
1
F001
---
1
F126
---
1
F126
---
1
F102
---
1
F001
---
1
F542
0 (Auto Overwrite)
%
1
F001
---
1
F102
Hz
0.01
F001
Hz
0.01
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
---
F205
---
1
F050
---
1
F001
---
1
F001
DEFAULT
"GE-UR-PMU"
0 (SRC 1)
1 (Class M)
0 (Integer)
0 (Polar)
B
4 (10/sec)
1 (Va)
0
0
"Dig Channel 1 "
0 (Off)
0
1
0 (None)
4712
4713
0 (Disabled)
0 (No)
0
0 (No)
0 (No)
0 (Disabled)
10
10
0 (Disabled)
4900
6100
10
100
0
0 (Self-reset)
0 (Disabled)
1 (Enabled)
(none)
0
0
0
B-65

Advertisement

Table of Contents
loading