I n p u t
n u m e r i c
p a s s w o r d :
( . . . . . . . . . . )
C L R
P a s s w o r d
i n c o r r e c t
CONFIGURATION
CHNG
XMTR
GEN
I / O
I NFO
CONF MEM
T A G : O L D T A G
N E X T
L A S T CHNG
O P T N O P T N
T A G : [ N E W T A G ]
< - -
- - >
C L R
T A G : N E W T A G
N E X T
L A S T CHNG
O P T N O P T N
D A T E : DD / MM / YY
1 1 / 1 1 / 0 0
N E X T
L A S T CHNG
O P T N
O P T N
D A T E : DD / MM / YY
[ 0 1 / 0 1 / 0 1 ]
<- -
- - >
D A T E : DD / MM / YY
0 1 / 0 1 / 0 1
N E X T
L A S T CHNG
O P T N O P T N
- 18 -

Use of the Green Key - Access to the CONF procedure

The access to the CONF procedure, as well as the TRIM and the
SER.LINK, can be protected by the use of a Password: if this option has
E N T R
been enabled then the following display will appears when the CONF
green key will be pressed .
Insert the numeric password using the numeric keys and the function key
labelled ENTER. If the password is correct the unit will proceed to the main
P R O
menu screen. Otherwise a warning message is displayed and the user is
C E E D
allowed to re-attempt entry. If the user makes a mistakes during entry, the
CLR key may be used to erase the input and start over.
The access to the above mentioned procedure remains possible until the
DBASE
unit is switched off. If the password is disabled then the access is
immediate and the Main Menu screen is suddendly displayed.

CONF - XMTR INFOrmation - TAG and DATE options

Using the CONF key, when the display with the message " SELECT
GREEN KEY" is present, the following display will appear:
Pressing F2, corresponding to "XMTR- INFO" (Transmitter Information )
you access the procedure of changing some information, these are the
TAG and the DATE: usually the TAG changing option is displayed: if a Tag
was already assigned to the transmitter, then it will appear on the display.
Using the F3 key, corresponding to CHaNGe, the next display will appear:
E N T R
Use key F1, F2 and F3 together with the keyboard (letters and numbers)
to input characters. Up to eight characters can be used to form the
tagname: the key CLR deletes the name inserted. When the full tagname
has been composed press ENTER to establish the communication with
the selected transmitter and store the new tag.
After some seconds the new display appears and, as you can see, the
new TAGname ( as an example NEWTAG ) has been included in the
display and in the transmitter's configuration. Use the key ESCAPE to
return to the previous display/s. Using the F1 key ( NEXT OPTioN ) it is
possible to select the Date changing procedure and the following display
will appear.
Using the F3 key, corresponding to CHaNGe, the next display will appear
with a blinking cursor visible in the date area.Using the numeric keypad
E N T R
it is possible to change the digit pointed by the cursor. The cursor shifts
automatically after each entry. In case of error shift backward using the
F1 key and digit the correct number. When the complete date is
composed press the F4, corresponding to " ENTeR" to establish the
communication with the selected transmitter. After some seconds, a new
display appears with the updated date. Using the ESCAPE key you can
return to the previous display/s.