To fix the detector (figure 5):
1)
Remove the upper cover.
2)
Loosen the screw and remove the front cover. WARNING: do not touch
mirrors or IR sensors!
3)
Loosen the two front screws and remove the sensors-electronic unit.
WARNING: do not touch IR sensors.
4)
Loosen the two screws and remove the rear cover.
5)
Fix the rear cover of the detector with screws and screw anchors.
6)
If you want to fix the detector on a supporting pole, insert two metal bands
(not provided) in the prearranged slots to block the detector to the pole.
3.2
Programming
The device programming is carried out through the DIP switch and the detector
acquisition by the control unit.
To program the detector:
1)
Power the detector with the provided battery. The LED flashes.
2)
Prepare the control unit to acquire the detector and select the required
area and memory location.
3)
Stimulate the detector by passing the hand in front of the sensors (the LED
will flash). The detector will transmit its code that will be acquired by the
Figure 5