GE N60 Instruction Manual page 445

Network stability and synchrophasor measurement system ur series
Hide thumbs Also See for N60:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 15 of 62)
ADDR
REGISTER NAME
3DAD
...Repeated for Field Latching Output 8
Field Unit Shared Outputs (Read/Write Setting) (16 modules)
3DC0
Field Shared Output 1 ID
3DC6
Field Shared Output 1 Operate
3DC7
Field Shared Output 1 Unit Dest 1
3DC8
Field Shared Output 1 Channel Dest 1
3DC9
Field Shared Output 1 Unit Dest 2
3DCA
Field Shared Output 1 Channel Dest 2
3DCB
Field Shared Output 1 Events
3DCC
...Repeated for Field Shared Output 2
3DD8
...Repeated for Field Shared Output 3
3DE4
...Repeated for Field Shared Output 4
3DF0
...Repeated for Field Shared Output 5
3DFC
...Repeated for Field Shared Output 6
3E08
...Repeated for Field Shared Output 7
3E14
...Repeated for Field Shared Output 8
3E20
...Repeated for Field Shared Output 9
3E2C
...Repeated for Field Shared Output 10
3E38
...Repeated for Field Shared Output 11
3E44
...Repeated for Field Shared Output 12
3E50
...Repeated for Field Shared Output 13
3E5C
...Repeated for Field Shared Output 14
3E68
...Repeated for Field Shared Output 15
3E74
...Repeated for Field Shared Output 16
Field Unit RTDs (Read/Write Setting) (8 modules)
3E80
Field Unit RTD 1Name
3E86
Field Unit RTD 1 Origin
3E87
Field Unit RTD 1 Type
3E88
...Repeated for Field Unit RTD 2
3E90
...Repeated for Field Unit RTD 3
3E98
...Repeated for Field Unit RTD 4
3EA0
...Repeated for Field Unit RTD 5
3EA8
...Repeated for Field Unit RTD 6
3EB0
...Repeated for Field Unit RTD 7
3EB8
...Repeated for Field Unit RTD 8
Field Unit Transducers (Read/Write Setting) (8 modules)
3ED0
Field Unit Transducer 1 Name
3ED6
Field Unit Transducer 1 Origin
3ED7
Field Unit Transducer 1 Range
3ED8
Field Unit Transducer 1 Min Value
3EDA
Field Unit Transducer 1 Max Value
3EDC
Field Unit Transducer 1 Units
3EDF
...Repeated for Field Unit Transducer 2
3EEE
...Repeated for Field Unit Transducer 3
3EFD
...Repeated for Field Unit Transducer 4
3F0C
...Repeated for Field Unit Transducer 5
3F1B
...Repeated for Field Unit Transducer 6
3F2A
...Repeated for Field Unit Transducer 7
3F39
...Repeated for Field Unit Transducer 8
Field Unit Identifiers (Read Only) (8 modules)
3F80
Attached Field Unit 1 Serial Number
3F86
Attached Filed Unit 1 Port Number
3F87
Attached Field Unit 1 Type
3F88
Field Unit 1 Status
GE Multilin
N60 Network Stability and Synchrophasor Measurement System
RANGE
UNITS
0 to 65535
---
0 to 65535
---
0 to 8
---
1 to 15
---
0 to 8
---
1 to 15
---
0 to 1
---
0 to 1
---
0 to 24
---
0 to 2
---
0 to 1
---
0 to 24
---
0 to 9
---
-9999.999 to 9999.999
---
-9999.999 to 9999.999
---
---
---
---
---
---
---
0 to 3
---
0 to 4
---
B.4 MEMORY MAPPING
STEP
FORMAT
DEFAULT
1
F205
"SO 1"
1
F300
0
1
F256
0 (None)
1
F001
1
1
F256
0 (None)
1
F001
1
1
F102
1 (Enabled)
1
F205
"RTD 1"
1
F253
0 (None)
1
F259
0 (100 Ohm Nickel)
1
F205
"TRD 1"
1
F253
0 (None)
1
F246
6 (0...20mA)
0.001
F004
0
0.001
F004
100000
---
F206
(none)
1
F205
(none)
1
F001
0
1
F243
0 (CC-05)
1
F262
0 (Disabled)
B
B-23

Advertisement

Table of Contents
loading

Table of Contents