Huawei OceanStor VIS6300 Quick Installation Manual
Huawei OceanStor VIS6300 Quick Installation Manual

Huawei OceanStor VIS6300 Quick Installation Manual

Oceanstor vis6000 series virtual intelligent storage system v100r001

Advertisement

OceanStor VIS6000 Series
Virtual Intelligent Storage System V100R001

Quick Installation Guide

Issue: 03
Part Number: 3150G070
Date: 2010-05-10
HUAWEI TECHNOLOGIES Co., Ltd.

Advertisement

Table of Contents
loading

Summary of Contents for Huawei OceanStor VIS6300

  • Page 1: Quick Installation Guide

    OceanStor VIS6000 Series Virtual Intelligent Storage System V100R001 Quick Installation Guide Issue: 03 Part Number: 3150G070 Date: 2010-05-10 HUAWEI TECHNOLOGIES Co., Ltd.
  • Page 2: Table Of Contents

    Contents Installation Environment Material List Installation Procedure Taking Antistatic Measures Installing the VIS6000 in the Cabinet Connecting Grounding Cable Connecting Storage Array and Application Server to the VIS6000 Connecting the Production Center to the Disaster Recovery Center Connecting the VIS6000 to the Maintenance Terminal Connecting Power Cable Power on Appendixes...
  • Page 3: Installation Environment

    Installation Environment The OceanStor virtual intelligent storage 6000 series virtual intelligent storage system (hereinafter referred to as the VIS6000 ) includes two products: VIS6300 and VIS6600. The VIS6600 is superior to the VIS6300 in hardware configuration and has more powerful capability of processing services. Unless otherwise specified, this document takes the VIS6000 with the AC power as an example.
  • Page 4: Material List

    Material List The N610E-22 cabinet is equipped with a captive nut mount bar. The material list includes grounding cables and power cables. 1 Tools Cross screwdriver Cutter Flathead screwdriver Cable tie Fiber binding strap Captive nut mount bar The plugged ESD-preventive wrist strap for the grounding Antistatic clothes Antistatic gloves...
  • Page 5 Paste labels on the connected cables to fill in related information. 3 Other Devices FC switch (take the Brocade 200E fiber channel switch as an example) Ethernet switch (take the HUAWEI Quidway S5600 series as an example) Maintenance terminal Application server (take DELL PowerEdge 2950 as an example)
  • Page 6 4 VIS6000 The VIS6000 supports Gigabit Ethernet (GE) port modules and Fiber Channel (FC) port modules. With full configuration, the VIS6000 can be configured with six port modules: ●Two FC port modules + four GE port modules ●Four FC port modules + two GE port modules ●Six GE port modules The VIS6000 provides ten interface cards with five on each side.
  • Page 7 Rear view of the VIS6000 (AC,two FC port modules+four Rear view of the VIS6000 (AC, four FC port modules+two GE port modules) GE port modules) Rear view of the VIS6000 (AC, six GE port modules) Rear view of the VIS6000 (DC,two FC port modules+four GE port modules) FC port module FC service port...
  • Page 8: Installation Procedure

    Installation Procedure Start Take antistatic measures Install the VIS6000 in the cabinet Install the VIS6000 in the cabinet Connect the grounding cable Connect the storage array and application server to the VIS6000 Connect the production center to the disaster recovery center Connect the VIS6000 to the maintenance terminal Connect power cable Power on the devices...
  • Page 9: Taking Antistatic Measures

    Taking Antistatic Measures 1 Wearing an Antistatic Wrist Strap Scenario 1: Wearing an Scenario 2: Wearing an Antistatic Antistatic Wrist Strap (Plugged) Wrist Strap (With Metallic Clip) When wearing an ESD-preventive wrist strap, for the plugged ESD-preventive wrist strap, insert the wrist strap into the ESD plug of the cabinet.
  • Page 10: Installing The Vis6000 In The Cabinet

    Installing the VIS6000 in the Cabinet 1 Specifying the Position of the VIS6000 in the Cabinet AC power distribution box (3U) Locate the VIS6000 Filler panel (2U) ▲ ■ If not specified, the VIS6000 in this document refers to the VIS6000 in the production center.
  • Page 11 Loosen the Screws on the Filler Panels Using a Cross Screwdriver Remove the Filler Panels 2 Locating and Installing Guide Rail Specify the Installation Positions of Guide Rail by Using the Installation Template...
  • Page 12 Install the Guide Rail Scenario 1: Installing the L-Shape Guide Rail Scenario 2: Installing the Adjustable Guide Rail The two parts of an adjustable guide rail are bound together with a binding strap. When you unfasten the binding strap, the two parts can slide freely. Be careful when you install the adjustable guide rail. Place the guide rail to be installed in the corresponding position, see step ①...
  • Page 13 3 Locating and Installing Captive Nuts Specifying the Installation Positions of Captive Nuts by Using the Installation Template Installing the Captive Nuts 3. Status After Installation 2. Insert the Other Foot of 1. Insert One Foot of the the Captive Nut into the Captive Nut into the Square Square Hole and Make it Hole and Make it Stuck to...
  • Page 14 Installing Fixed Bolt to the System Subrack Push the VIS6000 into the Cabinet Fix the VIS6000 in the Cabinet...
  • Page 15: Connecting Grounding Cable

    Connecting Grounding Cable Please connect the the cabinet to the grounding terminals of the VIS6000 with the grounding cable in the material list of the VIS6000. The grounding cables are wired on the right of the rear of the cabinet. 1 Connecting One End of the Grounding Cables to the Grounding Terminal of the VIS6000 Use a Cross Screwdriver to Loosen the Nut of the Grounding...
  • Page 16: Connecting Storage Array And Application Server To The Vis6000

    Connecting Storage Array and Application Server to the VIS6000 1 Confirming Connection Modes The networking modes in the production center or the disaster recovery center can both use the FC switch and the Ethernet switch. Please choose the networking mode according to the actual environment. This section takes the networking mode that uses only the FC switch or the Ethernet switch in the production center or the disaster recovery center as an example.
  • Page 17 Scenario 2: Networking for Connection of the Production Center and the Disaster Recovery Center (Only the Ethernet Switch Is Used in the Networking of the Production Center and the Disaster Recovery Center) Linux Windows Ethernet switch Ethernet switch Ethernet switch Ethernet switch VIS6000 VIS6000...
  • Page 18 Scenario 2: Connecting One End of the Network Cable to the GE Service Port of the VIS6000 Laying Cables The figures take the wiring inside the cabinet as an example. For the wiring outside the cabinet (overhead wiring and underfloor wiring) , see the appendixes. Scenario 1: Laying Optical Fibers...
  • Page 19 Scenario 2: Laying Network Cables Connect the Other End of the Cable to the Switch Scenario 1: Connecting the Other End of the Optical Fiber to the Port of the FC Switch...
  • Page 20 Scenario 2: Connect the Other End of the Network Cable to the Port of the Ethernet Switch 3 Connecting the Storage Array to the Switch The following section takes the OceanStor S5600 with FC and iSCSI host ports (hereinafter referred to as the S5600) as an example.
  • Page 21 Laying Cables The figures take the wiring inside the cabinet as an example. For the wiring outside the cabinet (overhead wiring and underfloor wiring) , see the appendixes. Scenario 1: Laying Optical Fibers...
  • Page 22 Scenario 2: Laying Network Cables...
  • Page 23 Connect the Other End of the Cable to the Switch Scenario 1: Connecting the Other End of the Optical Fiber to the Port of the FC Switch Scenario 2: Connect the Other End of the Network Cable to the Port of the Ethernet Switch 4 Connecting the Application Server to the Switch Connect One End of the Cable to the Port of the Application...
  • Page 24 Scenario 2: Connecting One End of the Network Cable to the Network Port of the Application Server Laying Cables The figures take the wiring inside the cabinet as an example. For the wiring outside the cabinet (overhead wiring and underfloor wiring) , see the appendixes. Scenario 1: Laying Optical Fibers...
  • Page 25 Scenario 2: Laying Network Cables Connect the Other End of the Cable to the Switch Scenario 1: Connecting the Other End of the Optical Fiber to the Port of the FC Switch...
  • Page 26 Scenario 2: Connect the Other End of the Network Cable to the Port of the Ethernet Switch...
  • Page 27: Connecting The Production Center To The Disaster Recovery Center

    Connecting the Production Center to the Disaster Recovery Center 1 Confirming the Mode in Which the Production Center and the Disaster Recovery Center Are Connected To connect the production center and the disaster recovery center, you can use the FC network (within 60 KM) or Ethernet.
  • Page 28 2 Connecting the VIS6000 in the Production Center to the Ethernet Switch Connect One End of the Cable to the GE Service Port of the VIS6000 Laying Network Cables This figure takes the wiring inside the cabinet as an example. For the wiring outside the cabinet (overhead wiring and underfloor wiring) , see the appendixes.
  • Page 29 Connect the Other End of the Cable to the Port of the Ethernet Switch 3 Connecting the VIS6000 in the Disaster Recovery Center to the Ethernet Switch For details about connecting the VIS6000 in the disaster recovery center to the Ethernet switch, see the operations about how to connect the VIS6000 in the production center to the Ethernet switch.
  • Page 30: Connecting The Vis6000 To The Maintenance Terminal

    Connecting the VIS6000 to the Maintenance Terminal Management network ports are not initially configured with IP addresses. You can manage the VIS6000 through management network ports only when you assign IP addresses to management network ports by configuring the configuration network port or the system debugging serial port in the command line interface (CLI).
  • Page 31 Connect the Other End of the Cable to the Network Port or the Serial Port of the Maintenance Terminal Scenario 1: Connecting the Other End of the Network Cable to the Network Port of the Maintenance Terminal Scenario 2: Connecting the Other End of the Serial Port Cable (convert RJ-45 to DB- 9) to the Serial Port of the Maintenance Terminal 2 Connecting the Management Network Port to the Ethernet Switch or the Maintenance Terminal...
  • Page 32 The management network port module on the VIS6000 has two management network ports (one on the left and the other on the right). This section takes the left management network port in the rear of the VIS6000 as an example. The process to connect the management network port on the right is similar. Laying Network Cables Perform the operation of the scenario corresponding to the type of the management network (direct connection networking or switch networking).
  • Page 33 Connect the Other End of the Network Cable to the Port of the Ethernet Switch or the Network port of the Maintenance Terminal Scenario 1: Connecting the Other End of the Network Cable to the Port of the Ethernet Switch When the Management Network Adopts the Switch Networking Scenario 2: Connecting the Other End of the Network Cable to the Network Port of the Ethernet Switch When the Management Network Adopts the Direct Connection Networking...
  • Page 34 Connect One End of the Network Cable to the Port of the Ethernet Switch Laying Network Cables For details on outside the cabinet wiring of network cables (overhead wiring and underfloor wiring) from the Ethernet switch to the maintenance terminal, see the appendix. Connect the Other End of the Network Cable to the Network Port of the Maintenance Terminal If the maintenance terminal is connected to the configuration network port of the VIS6000, it cannot...
  • Page 35: Connecting Power Cable

    Connecting Power Cable (AC Power ) Before connecting the power cables, ensure that all power switches are closed. Please use the AC power cables in the material list of the VIS6000. All power cables are wired on the left of the rear of the cabinet (when the power socket is on the right, lead the power cable that is plugged into the right socket to the left of the cabinet by using the wiring slot).
  • Page 36 Connecting Power Cable (DC Power ) Before connecting the power cables, ensure that all power switches are closed. Please use the DC power cables in the material list of the VIS6000. All power cables are wired on the left of the rear of the cabinet (when the power socket is on the right, lead the power cable that is plugged into the right socket to the left of the cabinet by using the wiring slot).
  • Page 37: Power On

    Power on Power on the devices in the following sequence: VIS6000 in the production center→VIS6000 in the disaster recovery center→ application server. Power on the devices in the production center and the disaster recovery center in the following sequence: cabinet→ storage array→switch→ VIS6000. 1 Setting the Power Switch on the API Module to ON To supply power redundantly, set the power switches of the two API modules to ON.
  • Page 38 Check the Status Indicator of the VIS6000 (Rear View) Status indicator of the system disk Link indicator of the FC service port Green, on Green, flashing Link indicator of the management Rate indicator of the FC service port Green, on Green, on network port Green, on...
  • Page 39 5 Installing the Baffle to the Front of the VIS6000 When you unpack the unpacking of devices, the front baffle of the VIS6000 is not installed. After setting the IP address of controller A and controller B and removing the cable, you can install the baffle to the front of the VIS6000 by using the buckles on the baffle.
  • Page 40: Appendixes

    Appendixes 1 Overhead Wiring of Optical Fibers in the Cabinet 2 Underfloor Wiring of Optical Fibers in the Cabinet...
  • Page 41 3 Overhead Wiring of Network Cables in the Cabinet 4 Underfloor Wiring of Network Cables in the Cabinet...
  • Page 42 HUAWEI TECHNOLOGIES CO., LTD. Huawei Industrial Base Bantian Longgang Shenzhen 518129 People’s Republic of China www.huawei.com...