Siemens SCALANCE XR324-4M PoE Compact Operating Instructions

Scalance xr-300m poe series. industrial ethernet switches
Hide thumbs Also See for SCALANCE XR324-4M PoE:
Table of Contents

Advertisement

Quick Links

SCALANCE XR-300M PoE
SIMATIC NET
Industrial Ethernet switches
SCALANCE XR-300M PoE
Compact Operating Instructions
05/2016
A5E02661178-10
___________________
Introduction
___________________
Safety instructions
___________________
Description
___________________
Installation
___________________
Connecting up
___________________
Technical specifications
___________________
Dimension drawings
___________________
Approvals
___________________
Appendix
1
2
3
4
5
6
7
8
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SCALANCE XR324-4M PoE

  • Page 1 ___________________ SCALANCE XR-300M PoE Introduction ___________________ Safety instructions ___________________ SIMATIC NET Description ___________________ Installation Industrial Ethernet switches SCALANCE XR-300M PoE ___________________ Connecting up ___________________ Technical specifications Compact Operating Instructions ___________________ Dimension drawings ___________________ Approvals ___________________ Appendix 05/2016 A5E02661178-10...
  • Page 2: Legal Information

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Introduction ............................. 5 Product group XR-300M PoE ....................7 Type designations ........................8 Safety instructions ........................... 9 Important notes on using the product group XR-300M PoE ............. 9 PELV ............................12 Important notes on using the device in hazardous areas ............12 Important notices 100 to 240 VAC ..................
  • Page 4 Table of contents Connecting functional ground ....................45 Signaling contact ........................46 5.3.1 24 V DC signaling contact (XR-300M) ................... 46 Diagnostics port ........................47 5.4.1 Diagnostics port rear ......................47 Power supply .......................... 48 5.5.1 Power supply XR-300M PoE ....................48 5.5.2 Connecting devices with 24 VDC power supply ..............
  • Page 5: Introduction

    With the Operating Instructions (compact), you will be able to mount and connect up the SCALANCE XR324-4M PoE and XR324-4M PoE TS correctly. The configuration and the integration of the relevant device in a network are not described in these instructions.
  • Page 6 Security messages Note Siemens offers IT security mechanisms for its automation and drive product portfolio in order to support the safe operation of the plant/machine. Our products are also continuously developed further with regard to IT security. We therefore recommend that you regularly check for updates of our products and that you only use the latest versions.
  • Page 7: Product Group Xr-300M Poe

    Introduction 1.1 Product group XR-300M PoE Product group XR-300M PoE Device Properties Order number XR324-4M PoE 1 x 24 VDC, PoE 6GK5 324-4QG00-1AR2 LEDs, connector power supply and data cable outlet on front Diagnostics port at rear. 1 x 100 to 240 VAC, PoE 6GK5 324-4QG00-3AR2 LEDs, connector power supply and data cable outlet on front Diagnostics port at rear.
  • Page 8: Type Designations

    Introduction 1.2 Type designations Type designations Structure of the type designation The type designation of an IE Switch X-300 is made up of several parts that have the following meaning: Interfaces of devices without optical ports: Interface Property Electrical RJ-45 port for 10/100 Mbps. Electrical RJ-45 port for 10/100 Mbps and 10/100/1000 Mbps.
  • Page 9: Safety Instructions

    Safety instructions Read the safety notices Note the following safety notices. These relate to the entire working life of the device. You should also read the safety notices relating to handling in the individual sections, particularly in the sections "Installation" and "Connecting up". Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING...
  • Page 10: Compact Operating Instructions, 05/2016, A5E02661178

    Safety instructions 2.1 Important notes on using the product group XR-300M PoE General information WARNING Safety extra low voltage The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS). (This does not apply to 100 V...240 V devices.) This means that only safety extra-low voltage (SELV) and limited power sources (LPS) complying with IEC 60950-1 / EN 60950-1 / VDE 0805-1 must be connected to the power supply terminals or the power supply unit for the equipment power supply must comply with...
  • Page 11 Safety instructions 2.1 Important notes on using the product group XR-300M PoE General notices regarding use in hazardous areas WARNING Risk of explosion when connecting or disconnecting the device EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR COMBUSTIBLE ATMOSPHERE IS PRESENT.
  • Page 12: Pelv

    Safety instructions 2.2 PELV PELV Note Safety extra-low voltage The supply of the devices by PELV (Protective Extra Low Voltage) according to DIN VDE 0100-410 or IEC 60364-4-41 is permitted when the generated nominal voltage does not exceed the voltage limits 25 VAC or 60 VDC. Important notes on using the device in hazardous areas WARNING WARNING - EXPLOSION HAZARD -...
  • Page 13: Important Notices 100 To 240 Vac

    Safety instructions 2.4 Important notices 100 to 240 VAC Important notices 100 to 240 VAC Note on devices with power supply 100 to 240 V AC WARNING Danger from line voltage The supply voltage for the devices listed is 100 to 240 VAC. This device can only function correctly and safely if it is transported, stored, set up, and installed correctly, and operated and maintained as recommended.
  • Page 14 Safety instructions 2.5 Safety requirements - Installation 100 to 240 VAC SCALANCE XR-300M PoE Compact Operating Instructions, 05/2016, A5E02661178-10...
  • Page 15: Description

    2. Check all the parts for transport damage. Components of the product XR-300M PoE Components that ship with the SCALANCE XR324-4M PoE and XR324-4M PoE TS switches The following components ship with a SCALANCE XR324-4M PoE or XR324-4M PoE TS: ●...
  • Page 16: Power Over Ethernet (Poe)

    ● PD - powered devices These are supplied with power via Ethernet. PoE ports of the SCALANCE XR324-4M PoE and XR324-4M PoE TS switches As PSEs, these devices supply PoE-compliant devices with power over Ethernet. The power required to supply the powered devices is generated internally on the switches, no extra power supply unit is necessary.
  • Page 17: Product Characteristics

    SCALANCE X-300 / X-400 on the accompanying CD. Product characteristics Connection options of the SCALANCE XR324-4M PoE and XR324-4M PoE TS switches The switches are partly modular devices and all have 24 ports. ● 16 fixed ports on the base device: –...
  • Page 18: The Set / Select Button

    Description 3.5 The SET / SELECT button CAUTION Use only approved modules in the slots Possible module connection types: • 2 x RJ-45 • 2 x FX100 • 2 x FX1000 • or 2 x SFP slots With FX, single mode fibers or multimode fibers are possible. Connecting end devices or other network segments does not depend on the module slots.
  • Page 19: Led Display

    Description 3.6 LED display Definition of the fault mask Using the fault mask, you specify an individual "good status" for the connected ports and the power supply. Deviations from this status are then displayed as errors/faults. 1. Turn on display mode A or D. Display mode A is active when the "DM" LED is not lit. Display mode D is active when the "DM"...
  • Page 20 Description 3.6 LED display The "SB" LED for the standby function This LED shows the status of the standby function. LED color LED status Meaning The standby function is disabled. green The standby function is enabled. The standby section is passive. green flashes The standby function is enabled.
  • Page 21 Description 3.6 LED display Pressing the SELECT/SET button Status of the "DM" LED Display mode starting at display mode A Press twice lit orange Display mode C Press 3 times flashes yellow/orange Display mode D The "L1" and "L2" or "L" LEDs for the power supply Whereas on other devices, the "L1"...
  • Page 22 Description 3.6 LED display Note Devices of the X-300EEC product group When using only one power supply unit 24 VDC and two 24 VDC power supplies, the LEDs "L1" and "L2" signal the existence of the power supply L1 and L2. When using two 24 VDC power supply units, the LEDs "L1"...
  • Page 23: C-Plug

    Description 3.7 C-PLUG Meaning in display mode C LED color LED status Meaning Port operating in half duplex. green Port operating in full duplex. Meaning in display mode D LED color LED status Meaning The port is not monitored; in other words, if a link is not established at the port, this does not trigger the signaling contact.
  • Page 24: Removal And Insertion Of The C-Plug (Rack Devices)

    Description 3.7 C-PLUG Principle The data remains stored on the C-PLUG even when power is turned off. In terms of using the C-PLUG, there are two ways of operating the device: ● With unwritten C-PLUG If an empty C-PLUG (factory settings or deleted with the Clean function) is inserted, all the configuration data of the device is saved to it automatically when the device starts up.
  • Page 25 Description 3.7 C-PLUG Removing the C-PLUG 1. Turn off the power to the device. 2. Remove the cover plate on the right-hand side of the device. 3. Insert a screwdriver between the front edge of the C-PLUG (posi- tion A) and the slot and release the C-PLUG. 4.
  • Page 26 Description 3.7 C-PLUG SCALANCE XR-300M PoE Compact Operating Instructions, 05/2016, A5E02661178-10...
  • Page 27: Installation

    Installation Safety notices for installation Safety notices When installing the device, keep to the safety notices listed below. WARNING If a device is operated in an ambient temperature of more than 50 °C, the temperature of the device housing may be higher than 70 °C. The device must therefore be installed so that it is only accessible to service personnel or users that are aware of the reason for restricted access and the required safety measures at an ambient temperature higher than 50 °C.
  • Page 28: Suitable Cables For Temperatures Above 70 °C - Cable 50 °C - 70 °C (Atex)

    Installation 4.2 Suitable cables for temperatures above 70 C - cable 50 C - 70 C (ATEX) Suitable cables for temperatures above 70 °C - cable 50 °C - 70 °C (ATEX) WARNING If the temperature of the cable or housing socket exceeds 70 °C or the branching point of conductors exceeds 80 °C, special precautions must be taken.
  • Page 29: Notes On Installation

    Installation 4.4 Notes on installation Note During installation and operation, keep to the installation guidelines and safety notices described in this document and in the system manuals "Industrial Ethernet / PROFINET Industrial Ethernet" and "Industrial Ethernet / PROFINET passive network components". You will find information on the system manuals in the section "Auto-Hotspot", in "Further documentation".
  • Page 30: 19" Rack Mounting

    Installation 4.5 19" rack mounting Note When installing and operating the device, keep to the installation instructions and safety- related notices as described in this document and in the manual SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks. 19"...
  • Page 31 Installation 4.5 19" rack mounting Minimum clearances If you install the IE Switch in rack devices without forced ventilation or cooling, minimum clearances must be maintained to neighboring devices or the wall of the enclosure. By keeping to the minimum clearances, there is then an adequate stream of air for heat dissipation during operation.
  • Page 32 Installation 4.5 19" rack mounting Normal orientation of the device The LED display is on the left of the front panel of the • housing. The connectors for the signaling contacts and the power • supply are on the right beside the LED display. The Ethernet ports or the slots for the modules are also •...
  • Page 33 Installation 4.5 19" rack mounting Normal orientation of the device The LED display is on the left of the front panel of the • housing. The diagnostics port of the device is also on the front of • the device. The ventilation grilles are on the top, bottom and sides of •...
  • Page 34 Installation 4.5 19" rack mounting Installation in a 19" rack 19" rack mounting Select the required rack device and the 19" cabinet. Fix the two mounting brackets with 4 screws each to the sides of the housing. The maximum tightening torque for these screws is 0.5 Nm.
  • Page 35: Vertical Installation Of Rack Devices

    Installation 4.6 Vertical installation of rack devices Spare parts Component Description Order number SCALANCE XR300 Rack Mount Kit Mounting bracket for 19'' rack installation; 6GK5980-2BA00-0AA4 for SCALANCE XR300; pack of 4; Vertical installation of rack devices Changed position of the mounting bracket Devices of the XR-300M category can also be installed vertically in a cabinet door.
  • Page 36: Installation Of Modular Devices

    NOTICE Use only approved media modules If you use media modules that are not approved by Siemens AG, there is no guarantee that the device will function according to the specification. If you use unapproved media modules, this can lead to the following problems: •...
  • Page 37 Installation 4.8 Installation of modular devices CAUTION Remember the orientation of media modules On modular devices, there are always two module slots arranged opposite each other. Remember the correct orientation when installing MM900 media modules. Example: • Install the first media module in slot 1. •...
  • Page 38 Installation 4.8 Installation of modular devices Installing a media module The media module is inserted with the handle pulled out. When the handle is inserted, the media module is locked in the device. Note The figures in the following installation instructions show the installation of a media module in a rack device.
  • Page 39 Installation 4.8 Installation of modular devices Push the handle back into the media module. This locks the media module in the device. Insert the connectors. Removing a media module CAUTION Risk of burns due to the high temperature of the module housing Turn off the device and allow the device to cool down before you remove a media module.
  • Page 40: Sfp Installation In Sfp Media Module

    NOTICE Use only approved SFPs If you use SFPs that are not approved by Siemens AG, there is no guarantee that the device will function according to the specification. If you use unapproved SFPs, this can lead to the following problems: •...
  • Page 41: Removing An Sfp

    Installation 4.8 Installation of modular devices Select the required SFP media module in the slot of the device. (Example: X-308-2M, slot 2) Insert the SFP with the clip closed in the SFP media module. Notice: Closing the clip after insertion does not lock the device in the rack.
  • Page 42 Installation 4.8 Installation of modular devices SCALANCE XR-300M PoE Compact Operating Instructions, 05/2016, A5E02661178-10...
  • Page 43: Connecting Up

    Connecting up Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Do not connect or disconnect cables to or from the device when a flammable or combustible atmosphere is present. Safety notices when using the device according to Hazardous Locations (HazLoc) If you use the device under HazLoc conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: WARNING...
  • Page 44: Notes On Commissioning

    Connecting up 5.1 Notes on commissioning NOTICE Failure of the data traffic due to contamination of optical plug-in connections Optical sockets and plugs are sensitive to contamination of the end face. Contamination can lead to the failure of the optical transmission network. Close unused optical sockets and plugs as well as pluggable transceivers and slots with the supplied protective caps.
  • Page 45: Connecting Functional Ground

    Connecting up 5.2 Connecting functional ground Connecting functional ground Optional grounding Grounding (functional ground) is via the mounting bracket on the device or via the screw-in bolts on the rear of the device. To ground the device from the back, follow the steps below: 1 toothed washer 2 grounding bolt The connector for the grounding cable is in the center of the rear panel of the device.
  • Page 46: Signaling Contact

    Connecting up 5.3 Signaling contact Signaling contact 5.3.1 24 V DC signaling contact (XR-300M) 24 V DC signaling contact Note Supply voltage at signaling contact for XR-300M and XR-300M-PoE At the signaling contact, there is always a voltage of 24 VDC even if the device can be operated with 100 to 240 VAC.
  • Page 47: Diagnostics Port

    Connecting up 5.4 Diagnostics port Diagnostics port 5.4.1 Diagnostics port rear Description Rack devices have a diagnostics port on the rear of the housing. This port is designed for an RJ-11 plug. A suitable connecting cable with an RJ-11 plug and a 9-pin D sub female connector for connection to the serial port of the PC ships with the SCALANCE XR-300.
  • Page 48: Power Supply

    Connecting up 5.5 Power supply RJ-11 plug D-sub 9-pin, female Assignment Assignment n. c. n. c. n. c. RD (Receive Data) TD (Transmit Data) TD (Transmit Data) SG (Signal Ground) n. c. RD (Receive Data) SG (Signal Ground) n. c. n.
  • Page 49: Connecting Devices With 24 Vdc Power Supply

    Connecting up 5.5 Power supply 5.5.2 Connecting devices with 24 VDC power supply 5.5.2.1 24 VDC - XR-300M PoE product group Table 5- 2 24 VDC safety extra-low voltage overview Device Device version (power supply) 24 V safety extra-low voltage (SELV) can be connected redundantly XR324-4M PoE...
  • Page 50 Connecting up 5.5 Power supply CAUTION Damage to the device due to overvoltage One of the tests used to attest the immunity of devices of the IE Switches X300 to electromagnetic interference is the "surge immunity test" according to EN61000 4 5. This test requires overvoltage protection for the power supply lines.
  • Page 51: Connecting Devices With 100 To 240 Vac Power Supply

    Connecting up 5.5 Power supply Spare parts Component Description Order number Terminal block 4-pin 4-pin terminal block for power supply 24 to 48 VDC; 6GK5980-1DB00-0AA5 for SCALANCE X,W,S,M; pack of 5; 5.5.3 Connecting devices with 100 to 240 VAC power supply 5.5.3.1 100 to 240 VAC XR-300M PoE product group Table 5- 4...
  • Page 52: Fitting The Connector For 100 To 240 V Ac

    Connecting up 5.5 Power supply 5.5.3.3 Fitting the connector for 100 to 240 V AC WARNING Danger from line voltage If used with cables with more than two wires, correct functioning of the connector casing cannot be guaranteed because the two halves of the connector casing can come apart. If this occurs, you will also not be able to connect all the wires in the connector.
  • Page 53: Connecting The 100 To 240 V Ac Power Supply

    Connecting up 5.5 Power supply Follow the steps below to fit the connector to a two-wire cable: 1. Connect the cable to the terminal block. Strip the cable jacket only as far as necessary to be able to strip the insulation and connect up the wires. 2.
  • Page 54 Connecting up 5.5 Power supply Spare parts Component Description Order number Terminal block 2-pin 2-pin terminal block for power supply 100 to 240 VAC incl. 6GK5980-1BC00-0AA5 housing; for SCALANCE XR300 pack of 5; Spare parts Component Description Order number Serial cable RJ-11/RS-232 preassembled, serial cable with RJ-11 and RS-323 6GK5980-3BB00-0AA5 plug;...
  • Page 55: Technical Specifications

    Technical specifications Note Validity of the technical specifications All the technical specifications described in this section that is not assigned to a specific device variant, version or a media module, apply to all device variants/versions of the product group. Construction, installation and environmental conditions Table 6- 1 Construction Dimensions (W x H x D)
  • Page 56 Technical specifications 6.1 Construction, installation and environmental conditions Table 6- 4 Operating temperature depending on the media modules used Media module Installation Operating temperature direction Without media module Horizontal -40 °C to +60 ℃ Vertical -40 °C to +50 ℃ MM992-2CUC Horizontal -40 °C to +60 ℃...
  • Page 57: Connectors And Electrical Data

    Technical specifications 6.2 Connectors and electrical data Connectors and electrical data Table 6- 5 Connection for end devices or network components Max. number 24 ports Electrical Port 1 to 8 8 x RJ-45 jacks, MDI-X pinning, 10/100/1000 Mbps (half/full duplex) power supply for connected devices (PDs) using Power over Ethernet (PoE) according to IEEE 802.3af / 802.3at (type 1)
  • Page 58 Technical specifications 6.2 Connectors and electrical data Table 6- 8 Electrical data: Overcurrent protection Device version Overcurrent protection of the power supply Non-replaceable fuse (power supply) 24 VDC T 5 A / 250 V 100 to 240 VAC T 2 A / 500 V Table 6- 9 Electrical data: Signaling contact Voltage via signaling contact...
  • Page 59: Cable Lengths

    Technical specifications 6.3 Cable lengths Table 6- 13 Pin assignment of the Ethernet ports of the SCALANCE PoE switch Pin number / wire Assignment for data transmis- Assignment for power transfer sion (PoE). Alternative A (MDI-X) Pin 1 Pin 2 Pin 3 Pin 4 Pin 5...
  • Page 60 Technical specifications 6.3 Cable lengths Table 6- 15 Permitted cable lengths (copper cable - gigabit Ethernet) Cable type Accessory (plug, outlet, Permitted cable length TP cord) IE FC Standard Cable, 4 × 2, 24 with IE FC RJ-45 Plug 180, 0 to 90 m 4 ×...
  • Page 61: Other Properties

    Technical specifications 6.4 Other properties Image 6-1 Block architecture of the XR324-4M Other properties Table 6- 16 Switching properties Max. number of learnable addresses 8000 Aging time 30 sec Switching technique Store and forward Latency 5 μs Table 6- 17 Reconfiguration times for redundancy mechanisms Redundancy mechanism Reconfiguration times...
  • Page 62 Technical specifications 6.4 Other properties Table 6- 18 Full wire speed switching Number of frames per second At a frame length of At 100 Mbps At 1000 Mbps 148810 1488095 64 bytes 84459 844595 128 bytes 45290 452899 256 bytes 23496 234962 512 bytes...
  • Page 63: Dimension Drawings

    Dimension drawings All dimensions in the drawings are in millimeters. Image 7-1 XR324-4M PoE and XR324-4M PoE TS: Front view Image 7-2 XR324-4M PoE and XR324-4M PoE TS: Side view Image 7-3 XR324-4M PoE and XR324-4M PoE TS: Rear SCALANCE XR-300M PoE Compact Operating Instructions, 05/2016, A5E02661178-10...
  • Page 64 Dimension drawings Image 7-4 XR324-4M PoE and XR324-4M PoE TS: From above SCALANCE XR-300M PoE Compact Operating Instructions, 05/2016, A5E02661178-10...
  • Page 65: Approvals

    Approvals XR-300M PoE approvals, certificates Approvals issued Note Issued approvals on the type plate of the device The specified approvals apply only when the corresponding mark is printed on the product. You can check which of the following approvals have been granted for your product by the markings on the type plate.
  • Page 66 (http://support.automation.siemens.com/WW/view/en/27069465)", in "Further documentation". – "EMC Installation Guidelines" configuration manual ID = 60612658 (http://support.automation.siemens.com/WW/view/en/60612658) ● Working on the device To protect the device from electrostatic discharge, personnel must first discharge any electrostatic charge from their body before touching the device.
  • Page 67 Approvals 8.1 XR-300M PoE approvals, certificates The product meets the requirements of the standards: ● Factory Mutual Approval Standard Class Number 3611 ● FM Hazardous (Classified) Location Electrical Equipment: Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and Non Incendive / Class I / Zone 2 / Group IIC / T4 Note Only variants with 24 VDC power supply meet the requirements of this approval.
  • Page 68: Scalance X-300 Declaration Of Conformity

    SCALANCE X-300 declaration of conformity (https://support.industry.siemens.com/cs/ww/en/ps/15296/cert) 1. Click on the entry "SCALANCE X-300 managed" in the navigation panel at the top edge of the window and from the drop-down list that opens, select the entry for your product group.
  • Page 69: Overview Of Xr-300M Poe Approvals

    Approvals 8.3 Overview of XR-300M PoE approvals Overview of XR-300M PoE approvals Table 8- 1 Overview of the approvals Device Variant c-UL-us c-UL-us c-UL-us C-TICK ATEX95 Inf. Tech. for Hazard- Ind. Cont. Zone 2 ous Loca- tions 1 x 24 VDC ●...
  • Page 70 Approvals 8.4 Mechanical stability in operation SCALANCE XR-300M PoE Compact Operating Instructions, 05/2016, A5E02661178-10...
  • Page 71: Appendix

    Appendix The connector system M12/X coded according to IEC 61076-2-109 Description M12 connectors with X coding are also suitable for transmission rates up to 210 Gbps (Cat6A) because the shields of the wire pairs can be led into the connectors. A further advantage is the availability of connectors with degree of protection IP67 with which the equipped devices are also suitable for adverse environmental conditions (dust, dampness).
  • Page 72 Appendix A.1 The connector system M12/X coded according to IEC 61076-2-109 SCALANCE XR-300M PoE Compact Operating Instructions, 05/2016, A5E02661178-10...
  • Page 73: Index

    Index ATEX, 11 Glossary, 6 Hazardous (Ex) area, 11 Safety instructions, 9 Safety notices for installation, 27 general, 9 Use in hazardous areas, 9, 27 SIMATIC NET glossary, 6 System manual, 29, 66 SCALANCE XR-300M PoE Compact Operating Instructions, 05/2016, A5E02661178-10...
  • Page 74 Index SCALANCE XR-300M PoE Compact Operating Instructions, 05/2016, A5E02661178-10...