Parameters For Brake Sequence Functions - Toshiba TOSVERT VF-S15 Instruction Manual

Functions for lift application
Hide thumbs Also See for TOSVERT VF-S15:
Table of Contents

Advertisement

4.4.1 Parameters for brake sequence functions

Title
Functions
f325
Brake releasing waiting time
Brake releasing small current
f326
detection level
f340
Creeping time 1
f341
Braking mode selection
f342
Load portion torque input selection
Hoisting torque bias input
f343
(valid only when f342=4)
f344
Lowering torque bias multiplier
f345
Brake release time
f346
Creeping frequency
f347
Creeping time 2
f348
Braking time learning function
f325
: Brake releasing waiting time
The brake release request signal is not output during f325 (Brake releasing waiting time)
setting time when the brake release.
The function is disabled when f325=0.00.
f326
: Brake releasing small current detection level
The inverter trip as low-current operation fault (uc) if the output current is f326 or less after
a lapse of f325 setting time when the brake release.
The function is disabled when f326=0.
f340
: Creeping time 1
Inverter suspends the braking request for the time set with f340 to minimize swing of load.
f341
: Braking mode selection
This parameter is to select operation mode of brake sequence function.
Usually, the forward (Terminal F) operation is winding up.
f342
: Load portion torque input selection
This parameter is to set the brake releasing torque value balanced with the load torque to
prevent load gap (shifts) at brake release.
Usually, set f342 = 4, and set the fixed value to f343 (Hoisting torque bias input) .
f343
: Hoisting torque bias input
This parameter is to set hoisting torque bias value and enabled only when f342 = 4.
The 100% value is the motor rated torque determined by f405 (Motor rated capacity) and
f417 (Motor rated speed).
Usually, set f343 =100. In case of trouble after brake learning, adjust this setting value.
Setting range
0.00-2.50 (s)
0-100 (%)
0.00 - 10.00 (s)
0:Disabled
1:Forward winding up
2:Reverse winding up
3:Horizontal operation
0:Disabled
1:Terminal VIA
2:Terminal VIB
3:Terminal VIC
4:f343
-250 - 250(%)
0 - 100(%)
0.00 - 10.00 (s)
f240 - 20.0(Hz)
0.00 - 10.00 (s)
0:Disabled
1:Learning (0 after adjustment)
20
Default setting
Setting sample
value
0.00
0.00
0
0
0.00
0
0
1
4
4
100
100
100
60
0.05
0.05
3.0
3.0
0.10
0.10
0
1