Weight And Physical Dimensions; Facility Requirements - Dell FC SAN User Manual

8/4 gbps
Table of Contents

Advertisement

A

Weight and physical dimensions

Weight and physical dimensions
Table 4
TABLE 4
Dimension
Height
Width
Depth
Weight

Facility requirements

The information in
FC SAN Module
TABLE 5
Condition
Temperature
Humidity
Altitude
Shock
Vibration
Air flow
28
lists the weight and physical dimensions of the 8/4Gbps FC SAN Module.
8/4Gbps FC SAN Module Specifications
Measurements
1.27 in (32.48 mm)
10.74 in (272.75 mm)
12.09 in (307.24 mm)
4.65 (2.10 kg) — without media
Table 5
shows the operating and non-operating limitations of the Dell 8/4Gbps
Environmental Requirements
Operating
32°F to 104°F (0°C to 40°C)
10% to 90%, non-condensing at
84.2°F (29°C)
Up to 10,000 ft (3,048 m)
20 G for 6 ms
0.4 G at 5-500 Hz
for 60 minutes
86 °F (30°C) Ambient: Approx. 3CFM
104°F (40°C) Ambient: Approx.
9CFM
Non-operating
-4°F to 158°F (-20°C to 70°C)
5% to 95%, non-condensing at
100.4 °F (38°C)
35,000 ft (10,668 m)
50G with velocity change of 4216
mm/sec squared
0.5 G at 2-200 Hz for 15 minutes
None required
Dell 8/4Gbps FC SAN Module Hardware User's Manual
53-1001964-01

Advertisement