Hitachi Compute Rack CR 210H User Manual page 64

Hide thumbs Also See for Compute Rack CR 210H:
Table of Contents

Advertisement

Error
code
2631
BIOS and ME are not compatible
2632
HECI is disabled
2633
ME Status is Invalid
2634
Cannot initialize HECI
Cannot enable Memory Mirroring
2250
Mode
Cannot enable Memory Lock Step
2251
Mode
Cannot enable Memory Sparing
2252
Mode
Notes:
(*1) Contact the sales representative or maintenance personnel.
(*2) Set correct information on the system BIOS setup menu.
If an error recurs, contact the sales representative or maintenance personnel.
(*3) Check if the memory boards are of correct configuration or installed normally.
If an error recurs, contact the sales representative or maintenance personnel.
When a RAID BIOS error message appears
A RAID BIOS "MegaRAID WebBIOS" message might appear. Take action
according to the description under "Action" in the table below.
Table 6-4: RAID BIOS error messages during POST
Cache data was lost because of an
unexpected power-off or reboot during a
write operation, but the adapter has
recovered. This could be because of memory
problems, bad battery, or you may not have a
battery installed.
Press any key to continue or press C to load
the configuration utility.
The memory/battery problems were
detected. The adapter was recovered, but
cached data was lost. Press any key to
continue or press C to load the configuration
utility.
Cache data was lost, but the controller has
recovered.
This could be due to the fact that your
controller had protected cache after an
unexpected power loss and your system was
without power longer than the battery
backup time.
Press any key to continue or press C to load
the configuration utility.
6-6
Error message
Error message
Troubleshooting
Hitachi Compute Rack 210H User's Guide
Description
A firmware error has been detected.
A HECI error has been detected.
A firmware error has been detected.
A HECI error has been detected.
A memory error has been detected.
A memory error has been detected.
A memory error has been detected.
Description
If this message appears even though an
illegal power shutdown or reboot is not
conducted during write operation,
contact the sales representative, or call
maintenance personnel.
If this message appears even though an
illegal power shutdown or reboot is not
conducted during write operation,
contact the sales representative, or call
maintenance personnel.
If this message appears even though an
illegal power shutdown or reboot is not
conducted during write operation,
contact the sales representative, or call
maintenance personnel.
Action
(*1)
(*1)
(*1)
(*1)
(*3)
(*3)
(*3)
Action
(*1)
(*1)
(*1)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Compute rack 220h