The following VDs are missing:
If you proceed (or load the configuration
utility), these VDs will be removed from your
configuration.
If you wish to use them at a later time, they
will have to be imported.
If you decide these VDs should be present,
power off your system and check your cables
to ensure all disks are present.
Press any key to continue or press C to load
the configuration utility.
The following VDs are missing complete
spans. If you proceed (or load the
configuration utility), these VDs will be
removed from your configuration and the
remaining drives marked as foreign.
If you wish to use them at a later time,
restore the missing spans and use foreign
import to recover the VDs.
If you believe these VDs should be present,
please power off your system and check your
cables to ensure all disks are present.
Press any key to continue, or 'C' to load the
configuration utility.
All of the disks from your previous
configuration are gone.
If this is an unexpected message, then
power off your system and check your cables
to ensure all disks are present.
Press any key to continue or press C to load
the configuration utility.
Your battery is either charging, bad, or
missing and you have VDs configured for
write-back mode. Because the battery is not
currently usable, these VDs will actually run
in the write-through mode until the battery
is fully charged or replaced if it is bad or
missing.
Press any key to continue.
Multibit ECC errors were detected on the
RAID controller.
The DIMM on the controller needs
replacement.
Contact technical support to resolve this
issue.
If you continue, data corruption can occur.
Press X to continue or else power off the
system and replace the DIMM module and
reboot.
If you have replaced the DIMM press X to
continue.
6-8
Error message
Troubleshooting
Hitachi Compute Rack 210H User's Guide
Description
Some of the disk array configurations
have been removed.
Some of the disk array configurations
have been removed.
All the HDDs with the disk array
configuration information have been
removed.
Cache backup module information is
illegal.
A cache memory error has occurred in
the disk array controller.
Action
(*4)
(*4)
(*4)
(*1)
(*1)