EMC Immunity
The SINAMICS PM230 has been tested in accordance with the immunity requirements of
category C3 (industrial) environment:
Table 7- 4
EMC Phenomenon
Electrostatic Discharge (ESD)
Radio-frequency Electromagnet-
ic Field
Amplitude modulated
Fast Transient Bursts
Surge Voltage
1.2/50 μs
Conducted
Radio-frequency Common Mode
Mains Interruptions & Voltage
Dips
Voltage Distortion
Voltage Unbalance
Frequency Variation
Commutation Notches
Note
The immunity requirements apply equally to both filtered and unfiltered units.
PM230 Power Module IP55
Hardware Installation Manual, 11/2014, A5E35319202B AA
EMC Immunity
Standard
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-11
EN 61000-2-4
Class 3
EN 61000-2-4
Class 3
EN 61000-2-4
Class 3
EN 60146-1-1
Class B
7.3 EMC overall performance
Level
4 kV Contact discharge
8 kV Air discharge
80 MHz ... 1000 MHz
10 V/m
80% AM at 1 kHz
2 kV @ 5 kHz
1 kV differential (L-L)
2 kV common (L-E)
0.15 MHz ... 80 MHz
10 V/rms
80% AM at 1 kHz
95% dip for 3 ms
30% dip for 10 ms
60% dip for 100 ms
95% dip for 5000 ms
10% THD
3% Negative Phase Sequence A
Nominal 50 Hz or 60 Hz
(± 45%)
Depth = 40%
Area = 250% x degrees
Appendix
Performance
Criterion
A
A
A
A
A
A
C
C
C
A
A
A
87