General Connection Diagram - Mitsubishi Electric C80 series Maintenance Manual

Hide thumbs Also See for C80 series:
Table of Contents

Advertisement

C80 Series Maintenance Manual
1 System Basic Configuration

1.2 General Connection Diagram

24VDC
FG
Basic
Power
Base
Unit
ACIN/DCIN
Source Power
AC/DC
24VDC or
100 to 240VAC
MPG#1
Manual Pulse Generator
UFO-01-2Z9 (5VDC)
Cable
G380 (Max:30m, for wiring outside the panel)
J395 (Max:10m, for wiring outside the panel)
J396 (Max:10m, for wiring inside the panel)
Drive Units
SKIP signals. 4 points (24VDC)
/ Manual Pulse Generator 2CH
MPG#2
MPG#3
<Notes>
Prepared by user
Used with connector. Cannot be used with cable H300 at the same time
(Note 1) HD60C (12VDC) requires another power source 12VDC.
Note
(1) A CPU module can be mounted on the CPU slot of the base unit or the slot No. 0 to 6. A slot between CPU modules
can be left empty for reservation. Note that you cannot mount an I/O module or intelligent function module on a slot
between CPU modules.
H101
cable
J303
cable
EMG
(Max:20m)
(Max:20m)
CPU Module
/ Network Module
EMG DISPLAY I/F
PLC
CNCCPU
CPU/
CPU
Module
Net-
Module
work
R16NCCPU
Module
Module
#1
H501
cable
(Max:0.5m)
H401
cable
(Max:20m)
H300
cable
(Max:20m)
Display module
GOT2000 Series
Specifications including unit names, cable
names, and maximum lengths of cables are
subject to change without notice. Always
confirm these details before placing an order.
24VDC or
100 to 240VAC
Dual Signal Module
CPU/
Dual
Dual
Dual
Net-
Signal
Signal
Signal
Module
work
Module
Module
Module
R173SXY
R173SXY
R173SXY
#2
H501
H501
cable
cable
Cable for terminal block
FA-CBLxxFMV-M
(Max:5m)
DClN
DClN
H310
cable
(Max:15m)
H010
cable
SKIP
(Max:5m)
TU l/F
MPG
Cable
G020 (5VDC, 1ch, Max:15m)
G021 (5VDC, 2ch, Max:15m)
G022 (5VDC, 3ch, Max:15m)
F020 (12VDC, 1ch, Max:45m)
F021 (12VDC, 2ch, Max:45m)
F022 (12VDC, 3ch, Max:45m)
3
MELSEC iQ-R I/O Module
/ Intelligent Module
I/O
I/O
I/O
I/O
I/O
I/O
Module
Module
Module
Module
Module
#1
#2
#3
#4
#5
#6
Machine I/O
/Operation panel
Terminal block type
FA-TBS40P
24VDC
Terminal block type
FA-TBS40P
24VDC
SKIP signals. 4 points (24VDC)
Signal splitter
SW
FCU7-HN387
TERMINAL
DCIN
24VDC (Not used)
(12VDC) (Note1)
MPG#1
MPG#2
MPG#3
Manual Pulse Generator 3CH
UFO-01-2Z9 (5VDC)
HD60C (12VDC)
(Note1)
IB-1501454-C

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading