C80 Series Maintenance Manual
1 System Basic Configuration
1.4.1.2 Q61P/Q63P/Q64PN
Q63P
No.
Name
(1)
POWER LED
(1)
Q61P/Q64PN
ON (Green):
Normal (5VDC output, instantaneous power failure within 20ms)
OFF:
The power supply module is out of order while AC power supply is ON. (5VDC error, in-
ternal circuit failure, blown fuse)
Over current protection or over voltage protection operated.
AC power supply is not ON (including power failure and an instantaneous power failure
of more than 20ms)
Q63P
ON (Green):
Normal (5VDC output, instantaneous power failure within 10ms)
OFF:
The power supply module is out of order while DC power supply is ON. (5VDC error, in-
ternal circuit failure, blown fuse)
Over current protection or over voltage protection operated.
DC power supply is not ON (including power failure and an instantaneous power failure
of more than 10ms)
Q61P/Q64PN
Details
7
(1)