Haier HI50IB Installation And User Manual page 12

Automatic undercounter ice machine
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION INSTRUCTIONS
CONNECT THE WATER
Tools Needed:
• ½" Open-end Wrench
• Phillips Screwdriver
• Adjustable Pliers
CONNECT THE WATER LINE
1. Turn off the main water supply. Turn on the nearest faucet long enough to
clear line of water.
2. Find a ½" to ¾" vertical cold water pipe near the installation location. The
water supply hose is provided with the ice machine.
3. A shut-off valve must be installed to the main water supply. If the water
pipe has a plain piece of copper tubing, attach a ¼" outside diameter
(O.D.) compression union to the tubing and remove the nut.
4. Connect the nut from the water supply hose to the tap, and connect the
other end to the water inlet. Tighten firmly by hand, and then using a
wrench tighten an additional half turn.
5. Turn on main water supply and tap.
6. Check for water supply connection leaks. Tighten every connection
(including connection at the water inlet).
IMPORTANT: When you connect the water supply hose and the drain hose,
note the "Water inlet" and "Drain outlet" marked on the ice machine.
CONNECT THE DRAIN
You must connect the drain line before using the ice machine.
NOTE: If there is a drain line near the ice machine, the best choice is to drain
water to the drain line through the drain water hose provided with the ice
machine.
1. Locate the floor drain near the ice machine. The distance should be less
than 5 feet since the length of the long drain water hose provided with
the ice machine is about 5 feet.
2. Find the drain outlet on the back of ice machine. Connect the drain hose
to the ice machine drain outlet, tighten drain hose clamp, and insert the
other end of the hose into the drain line.
12
(Cont.)
49-60811